Pre – Lighting Check and Commissioning
Check all Building Regulations have been adhered to.
The baffle plate is in the right position.
A smoke test has been done to check the chimney is clear.
Data Plate
All stoves are numbered and performance marked on a data plate which is found on a swinging
arm located at rear of the stove.
Air Vent
Under part J of building regulations an air vent of the appropriate size must be fitted for all
stoves with a kw rating of over 5kw.
Very air tight properties designed with air permeability less than or equal to 5.0 m3/ (h.m2) per
hour, an air vent will need to be fitted for all kilowatts.
It must be considered when fitting air vents that it is taken into account any other appliance
fitted within the room.
Please Note: Extractor fans when operating in the same room or space as the appliance may
cause problems.
Air vent inlet grills must not be inadvertently blocked.
Air vents must not be fitted in positions where they can be inadvertently covered up.
st
As from the 1
October 2010 a compliant Carbon Monoxide Alarm must be fitted
Table of mean flue temperatures with closed doors
Stove Type
Sherford Slimline 5 SE
Flue Gas Mass Flow
Stove Type
Sherford Slimline 5 SE
Stove Performance
Sherford Slimline 5 SE
All stoves are tested to nominal outputs and will well exceed these kilowatt ratings.
Flue gas temp downstream of spigot, closed doors.
Flue gas mass flow (g/s)
Wood burning 5kW nominal 81.6% Net Efficiency
10
Wood logs
218°C
Wood logs
4.0