Kontrol Ünitesi Jafar 2901 için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. Jafar 2901 10 sayfaları. Flange-to-flange gate valves with soft seals and pneumatic actuators
The gate valve marking meets the following standards: PN-EN-19: 2005, PN-EN-1074-1: 2002. The
valve bodies feature markings on the front and back walls of the body chamber. The marking contains the
following data:
The location on the valve specified in the documentation features the nameplate which contains the
following data:
3 PROTECTION, STORAGE & TRANSPORT
3.1 PROTECTIVE COATINGS
All inner and outer cast-iron surfaces are protected with electro-deposited epoxy coat. The coat has been
approved for contact with foodstuffs.
The anti-corrosion coating layer minimum thickness is 250 µm. The casting surface is pre-treated for epoxy
coating in accordance with the relevant technical documentation and PN-EN ISO 12944-5:2009. The cover-to-
body fastening bolts are grade OH18N9 or Fe/Zn5 (galvanised steel).
3.2 PACKAGING
The gate valves are packed on EURO pallets (1200x800) and protected with heat-shrunk film.
3.3 STORAGE
Store the gate valves in sheltered rooms.
- valve type (defined by the product reference standard number)
- nominal diameter
- nominal pressure
- body material type
- manufacturer trademark
- manufacturer's company name and logo
- serial number
- sealing temperature grade
- the Polish Building Mark "B" and/or the CE mark (as applicable)
- product type
OPERATION AND MAINTENANCE MANUAL
09-2015