Fitting Instructions for the Dean Stoves 105Se inset
Introduction
Before lighting the stove check that all installation instructions have been carried out.
Health And Safety Precautions
All work must be carried out to the requirements Health and Safety at Work Act 1974.
There must not be an extractor fan fitted in the room.
There must be an air vent for all stoves of 5 kilowatt and over or meet current building
regulations.
Stoves must be fitted to BS8303, BS6461 PT1-2 1984 building regulations.
All local regulations, including those referring to national and European standards need to be
complied with when installing the appliance.
N.B
A suitably qualified person must fit the stove. i.e. a HETAS engineer or with the supervision of
building control.
As with all stoves, fireguards must be installed when young children are present.
Surround Frame
The 105Se inset is supplied with an extension frame. This frame can be used when the
fireplace aperture cannot be covered by the stove alone. The frame sits behind the stove front
before the stove is secured into the fire place aperture.
Securing the stove
The stove must be securely fixed to the hearth via the securing hole in the base of the stove. To
access this securing hole, you will need to remove the great. A 120mm Torx screw (T30) and
washer (pre drill 5mm) is supplied with the stove, if this bolt is not sufficiently long enough for
the application then an appropriate bolt or fixing must be sourced and used. It is up to the
installer to adequately secure the stove into the fireplace.
Chimney, Flue Connections and Outlets
All Dean Stoves must have a minimum chimney height of 4m measuring from the stove outlet,
the chimney must not be less than 150mm (6") internal diameter unless a smoke control kit is
fitted. If a smoke control kit is fitted a 125mm (5") internal diameter liner can be used. We
recommend a 150mm liner should be used where possible even if a smoke control kit is fitted.