Adexa 6G-TRH60 Kurulum ve Çalıştırma Talimat Kılavuzu - Sayfa 6

ızgara Adexa 6G-TRH60 için çevrimiçi göz atın veya pdf Kurulum ve Çalıştırma Talimat Kılavuzu indirin. Adexa 6G-TRH60 20 sayfaları. Gas lava rock grill

SPECIFICATION

General

The appliance is designed for commercial purposes, not for household use!
The product is a series of gas char broilers in our company production, which is novel designed, reasonable
structured, convenient operated, durable used, and convenient maintained. It's equipped with a high
efficiency stainless steel tubular burner, combining flame out protection device and electronic pulse ignition,
and convenient to ignite the main fire burner. This is hotel, supermarket, western restaurant, noshery and
food industry's ideal cooking product equipment.

Pack Contents

The following is included:
The Gas LAVA ROCK GRILL
Four Feet
Instruction Manual
The gas lava rock

Product specification list:

3.
Model
Dimension (mm)
Height of working table
Gas inlet size
Gas
Orifice dia.
G30
1.3mm
G30
1.2mm
G30
1.1mm
G20
2.2mm
G25.3 2.2mm

Pressure point:

The burner operating pressure is to be measured at the manifold test point with one or two burners
operating at full setting. The operating pressure is ex-factory set, through the appliance regulator and is
not to be adjusted.

Gas connection:

Gas connection shall be fixed with the matched gas adaptor with seal gasket to suit for various
national situation.

Feet adjusting height:

Gas pressure.
6G-TRH60
29mbar
6kW x2
37mbar
6kW x2
50mbar
6kW x2
20mbar
7.5kW x2
25mbar
7.3kW x2
100-140mm
6G-TRH40
400×650×540
335
R1 1/2"
Total power
6G-TRH40
6kW
6kW
6kW
7.5kW
7.3kW
4
6G-TRH60
600×650×540
335
R1 1/2"