● Not all the following problems are malfunctions.
PROBLEM
Dehumidifier is not operating.
Controls cannot be set.
Noise suddenly starts when
operating
Humidity does not drop.
Humidity does not drop.
Little or no effect in
dehumidifyng
When first turned on, the air
emitted has musty-odor.
Unit has noises.
Swooshing sound is heard.
● Problem of Water Leakage.
PROBLEM
When using the drain
hose, there is water in
the bucket.
● Unit is operating in an area where the temperature
is higher than 32°C or lower than 5°C.
● Bucket is full.
● Noise will be heard if the compressor has just started.
● Power supply problem.
● Unit is placed on uneven floor.
● Area to be dehumidified is too large. The
capacity of your dehumidifier may not be
adequate.
● Doors are open.
● There might be a device producing
vapor in the room.
● Room temperature is too low.
● Humidity level may be improperly set.
● If unit is operating in a room where tempera-
ture is from 5 to 15 °C, it will start to defrost
automatically. Compressor will stop for a brief
period of time (fan will operate a high fan
speed). When unit finishes defrosting, it will
go back to normal operation.
● Due to increased temperature of heat exchanger,
the air may smell strangely at the beginning.
● There might be some noise if unit is operating
on a wooden floor.
● Normal. This is the sound of the flow of refrigerant.
Possible causes
● Examine the drainage
joint.
● Drain hose is not
correctly installed.
● Drain hose is not
correctly installed.
POSSIBLE CAUSES
Solu ons
● Connect the drainage
joint well.
● Unblock the drain hose.
● Remove the drain hose
and replace it. Be sure
that the hose is correctly
installed.