OPERATION OF WIRED CONTROLLER

Temperature Display Mode

The wired controller LCD display may display either room temperature sensed at the system,
room temperature sensed at the wired controller, or return air temperature sensed at the
indoor unit.
To set the temperature display, the unit must be in the "Off" State. Press Function and Timer
buttons at the same time for 5s. The temperature display will show 00. Press the Mode button to
select the Display Code for the desired temperature display. Press Enter to save the section.
Press the Function & Timer Buttons
Display
Code
01
Return air temperature sensed at the return air inlet.
02
Indoor ambient temperature sensed at the wired controller.
Return air temperature sensed at the return air inlet during Cooling, Dry and Fan modes.
03
And display the indoor ambient temperature sensed at the wired controller during Heating & Auto modes.
Indoor ambient temperature sensed at the wired controller during Cooling, Dry and Fan Only modes.
04
And return air temperature sensed at the return air inlet during Heating & Auto modes.
Factory default setting is Display Code 03.
CAT NO: GREE_X60_OWNERS_112918
Select with Mode Button Press
Temperature Display Mode
Enter button to save.