MAINTENANCE
Use suitable instruments for the refrigerant R410A.
Do not use any other refrigerant than
Do not use mineral oils to clean the unit.
INSTALLATION DIMENSION DIAGRAM
The installation must be done by trained and qualified service personnel with reliability according to this
manual.
Contact service center before installation to avoid the malfunction due to unprofessional installation.
When picking up and moving the units, you must be guided by trained and qualified person.
Ensure that the recommended space is left around the appliance.
Fix the support of outdoor unit (select it according to the actual installation situation)
1.
Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion
screws.
NOTICE:
Take sufficient protective measures when installing the outdoor unit.
Make sure the support can withstand at least four times of the unit
weight.
The outdoor unit should be installed at least 3cm above the floor in
order to install drain joint. (for the model with heating tube, the
installation height should be no less than 20cm.)
For the unit with cooling capacity of 2300W ~ 5000W, 6 expansion
screws are needed; for the unit with cooling capacity of 6000W~
8000W, 8 expansion screws are needed; for the unit with cooling
capacity of 10000W~16000W, 10 expansion screws are needed.
As for the shape of drainage joint, please refer to the current product.
Do not install the drainage joint in the severe cold area. Otherwise,
it will be frosted and then cause malfunction.
R410A.
30cm or above
Space to the cover
200cm or above
(Air outlet side)
50cm or more
Space to the cover
at least 3cm above the floor
12
INSTALLER
INSTALLER
30cm or above
(Air inlet side)