Specifications
Cold Water Supply
Dynamic Water Pressure
Min: 0.2 bar
Max: 5.0 bar
3.0
3.0
2.0
2.0
4.0
4.0
1.0
1.0
0.
5.0
0.
5.0
Min: 5°C Max: 25°C
Pressure
Pressure
BAR
BAR
IMPORTANT
Maximum Static Pressure: 10.0 bar
Tools You'll Need
Flat head
Socket Spanner
Drill
Adjustable Spanner
Screwdriver
Prior to Installation
All products manufactured and supplied by Bristan are safe to use
provided that they are installed, operated and receive regular
maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999
and current by-laws. For full Installation Requirements & Notes (IRN)
please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease
of future maintenance. Before installing this product the water supply
must be thoroughly flushed in order to remove any swarf, solder etc.
Full access must be made available for future maintenance/
servicing purposes.
Before drilling into walls, check that there are no hidden electrical
wires, cables or water supply pipes. This can be checked with the
aid of an electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way
as this will invalidate the guarantee.
If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Code: AR3 SHCDIV C (D7)
Inlet Water Temperature
Inlet Dimensions
Hot Water Supply
65°C
25°C
5°C
65°C Recommended
The inlet hot water must
be at least 10°C above the
required blend temperature.
Pipe Cutter
Silicon Sealant
Crosshead Screwdriver
Cavity Dimensions (mm)
Minimum
Cavity Depth: 35mm
Concealing Plate
Adjustment Range: 30mm
Pack Contents
x1
x1
x2
x1
x2
Valve Configuration
1
Yellow Flow
Limiter (Hot)
Installation
150
1
Centres
Max 45mm
Install suitable
batons
Inlet Connections
(if required) onto
the rear cavity.
15mm
Mark the position
Compression
of the valve
and drill and plug
holes to suit.
Min 35mm
3
Pipe & Wire Detector
Hot
Connect the inlet
pipes ensuring the
35
olives are fitted.
30
45
6
Fit the handles.
x2
2
Decrease
Temperature
x2
Green Flow
Limiter (Cold)
Remove the inlet elbows and filters.
Remove the plastic inserts from the valve
inlets and insert the flow regulators.
Replace the elbows, ensuring the
filters are fitted.
2
Secure the valve using the screws supplied
(solid walls only) or a suitable alternative.
Baton
4
Cold
Plumb the valve into
your chosen outlet.
Turn on the water
supply and check the
valve for any leaks.
Temperature Adjustment
1
2.5
mm
3
Turn the spindle
to increase or
decrease the
Fit the
temperature.
temperature
Check the
handle back in
the maximum
temperature and
hot position.
adjust until you
Increase
Temperature
achieve the
desired result.
2
Screw the shrouds
onto the valve.
5
Draw around
the concealing
plate as a template,
measuring in by
10mm to give
clearance. Finish the
wall surface. Using a
silicon sealant, push
on the concealing
plate and hold
firmly until set.
Turn the handle to the
maximum temperature
setting, then remove it.