Bristan H64DMT2 Kurulum Talimatları ve Kullanım Kılavuzu - Sayfa 4
Sıhhi Tesisat Ürünleri Bristan H64DMT2 için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım Kılavuzu indirin. Bristan H64DMT2 20 sayfaları. Single sequential d08 tmv3 thermostatic mixer taps
Specification
Inlet connections:
15mm Compression with 150-200mm
adjustable centres.
Operating pressure range:
Min. 0.2 Bar - Max. 5.0 Bar
Maximum recommended imbalance
between hot and cold supply should
not exceed a ratio of 5:1.
If the fitting is installed at low
pressure (tank fed), then the
minimum distance from the outlet
to the underside of the cold tank
should be at least 2 metres to ensure
adequate performance.
Note: Nominally equal (balanced)
inlet supply pressures are
recommended for optimum
performance with mixer taps.
Maximum Static Pressure: 10 Bar
TMV3 Designation:
HP-WE & LP-WE
Maximum Outlet Temperature:
Factory pre-set to 41°C
The temperature can be reset to suit
site conditions. If the temperature is
re-set to suit different site conditions
the mixer will work adequately
however the TMV3 scheme may not
apply.
Recommended Usage
Domestic
Light
Commercial
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
4
Supply requirements:
Minimum cold water supply
temperature: 5°C.
Maximum cold water supply
temperature: 25°C.
Maximum hot water supply
temperature: 80°C.
A maximum hot water supply
temperature of 60 - 65°C is
recommended for ablutionary
purposes. BS 8558 recommends
hot water should be stored and
distributed at a temperature of
no less that 60°C which will help
minimise the build-up of lime scale in
hard water areas.
Note: The inlet hot water
temperature must be at least
10°C above the required blend
temperature (eg. mixer temperature
41°C: minimum hot supply 51°C).
Flow Regulators
This product is supplied fitted with
a yellow 5 l/p/m (Hot) and a Olive
2 l/p/m (Cold) flow regulator which
should remain fitted for both high
and low pressure systems.
If the flow regulators are replaced
they must be fitted as below;
Yellow 5 l/p/m - Hot outlet
Olive 2 l/p/m - Cold outlet
Heavy
Commercial
Health Care