Installation Requirements
IMPORTANT - PLEASE READ
This/these f itting/fittings needs/need to be
installed in accordance with the following
Installation Requirements and Notes [IRNI to
ensure they m eet the requirements of the
Water Supply [Water Fittings! Regulations 1999
and the Scottish Byelaws 2004.
IRN R001: HOU½ C, HOU¾ C, HOU BAS
C/BLK, HOU BF C/BLK, HOU BSM C/BLK
See text of entry for Installation Requirements or
Notes.
IRN R005: HOU BF C/BLK, HOU BSM C/BLK
This tap or combination tap assembly has a Type
AUK2 air gap and is therefore only suitable for
domestic
installation in
premises to protect against a backflow risk up to a
Fluid Category 3, unless additional backflow
protection for the higher risk is included in the
installation.
IRN R006: HOU½ C, HOU¾ C, HOU
BAS C/BLK This tap or combination tap is
installed so that its base is no lower than the
spillover level of the
example, a sink or washbasin]. a Type AUK3 air
gap is achieved which permits installation of the
tap in any premises where backflow protection
up to Fluid Category 5 is required at the tap.
IRN R010: HOU BAS C/BLK, HOU BF C/BLK
Schedule 2-15111
Water supplies shall be a reasonably balanced
pressures from a common source [e.g. hot and
cold supplies both from the same storage or both
from a supply pipe]. Where the fitting is supplied
from unbalanced supplies [e.g. hot and cold
supplies from separate sources] a 'Listed' single
check valve or some other no less effective
backflow prevention device shall be fitted
immediately upstream of both hot and cold water
inlets.
06
premises or in other
receiving
vessel [for
IRN R030 - HOU BSM C/BLK - Schedule 2-15
[11Multiple inlet fittings installed in domestic
premises or in other premises to protect against
a backflow risk up to a Fluid Category 3,
incorporating a self cancelling diverter
acceptable as a backflow prevention device [HC]
and having an AUK2 or AUK3 air gap, shall be
accordance
installed in
Multiple inlet fittings installed in premises other
than domestic to protect against a backflow risk
up to a Fluid Category 5, incorporating a self
cancelling
diverter acceptable as a backflow
prevention device [HC only] and having an AUK2
or AUK3 air gap, shall be installed in accordance
with IRN R010. Alternatively the fitting shall be
supplied in accordance with IRN R040 unless the
shower head is constrained above the spill-over
lever of the bath, wash basin or shower tray.
with IRN R010.