Installation
1. Fit The Spout
Fit the spout to the sink / work surface
ensuring the sensor cable is threaded
through the hole in the sink / work
surface.
Also ensure that the product is at least
360mm away from reflective surfaces
to prevent the tap from automatically
switching on and off.
2. Secure Spout to Sink / Work Surface
Thread the rubber washer and metal
washer onto the fixing rod up to the
underside of the sink / work surface.
Secure the spout in place by screwing
the fixing nut onto the fixing rod.
Tighten the fixing nut using a suitable
spanner.
3. Connect Sensor Cable
See 'Electrical Connections' installation.
4. Connect Water Supplies
See 'Water Connections' installation.