Maintenance Cont.
Cleaning the Cartridge
If your fitting begins to leak the
following should be carried:
Isolate both hot and cold water
supplies to the tap by either:
• Turning the water supplyoff at the
mains stopcock or
• Turning off the isolation valves to
the tap.
1. Remove the grub screw, located
at the rear of the handle using a
hexagonal key.
2. Remove the handle by pulling
upwards from the spacer; proceed
to remove spacer and shroud.
3. Using a suitable spanner remove
retaining nut to gain access to the
cartridge.
4. Lift out the cartridge and clean
thoroughly. Be sure to check and
clean out the seating within the tap
body.
5. If necessary replace the cartridge.
6. Place the cartridge into the tap
body and tighten the retaining nut
fully using a suitable spanner.
7. Replace Shroud, spacer and handle
ensuring to refit grub screw.
8. Turn on water supply and check for
leaks.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
14