Troubleshooting

Symptom
'99' flashing in the
'Set Temperature' display.
Water/Steam is spitting
from the spout.
Water is not hot.
Water is too hot.
Water is dripping
from the spout.
Slow flow from the spout.
Water doesn't flow straight
away.
No water flowing.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
14
Cause
Boiling Water Tank is empty at
first switch-on.
Boiling Water Tank isn't
holding water.
Unit is boiling.
The Boiling Water Tank is
unplugged.
The Boiling Water Tank is not
switched on.
Water hasn't finished
heating up.
The water temperature is set
too high.
Residual water tension.
The Expansion Chamber isn't
draining correctly.
Blocked spout.
Water Filter needs changing.
This appliance is designed
for non-pressurised
operation. There will be a
slight delay until the instant
hot water appears.
Closed/Partially closed
isolation valves.
Flexible tails kinked/blocked.
Boiling Water Tank may be
blocked.
Remedy
Follow the Preparation for Use section.
Check connections for any leaks.
Contact Customer Services.
Turn the Instant Hot Water Tap
handle and release the water.
Adjust the water temperature to a
lower setting - See Operation.
Check the aerator isn't blocked.
Follow the Preparation for Use section
to remove any airlocks.
Make sure the appliance is plugged in
and the display is lit.
Make sure the circuit breaker and fuse
are working correctly.
Follow the Start-Up steps (pg10) and
wait until the Status Arc is fully lit
before use.
Set the water temperature to a
lower setting - See Operation.
This is caused the build up of water in
the tap body and is normal for a short
period of time.
Draw off 500ml of water to clear and
prime the system. Avoid
drawing off less than 150ml per use.
See Maintenance Section to
Clean Aerator.
Refer to the Maintenance Steps to
change the water filter. This must be
changed every 6 months or it will
invalidate the guarantee.
After a large volume of water has
been drawn off, there may be a
slightly longer delay in water
appearing from the Instant
Hot Water spout.
Make sure isolation valves are fully
open.
Ensure pipes are not twisted or kinked
to restrict flow.
Contact Customer Services.