Problem
The compressor works
abnormally with a buzzing
noise
Water shortage indicator
light is on
Indicator lights on display are
not on
The ice is too large
and pieces are sticking
together.
Conditions for ice-making
cycle are all in order but no
ice is coming out.
Indicator lights for "FULL"
and "DEFICIENT" light up
at the same time
•
If the power cord is damaged; it must be replaced by the manufacturer, its service agent or a qualified
person in order to avoid a hazard.
•
Fill only with potable water.
•
It is normal for the compressor and condenser surface to reach temperatures between 70°C and 90°C
during operation. Surrounding areas may be very hot.
•
Due to fast freezing, ice cubes may appear "Cloudy". This is air trapped in the water and will not
affect quality or taste of ice.
•
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities or lack of experience and knowledge unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
•
Do not immerse in water
Possible Cause
The voltage is lower than
recommended
There is no water
Blown fuse/ No power
The water temperature in
the water storage box or
ambient is too low
Refrigerant leaks /
Sealed system is blocked
Water tray is blocked by ice
cube
ADDITIONAL REMINDERS
Suggested Solutions
Stop the Ice Maker and do not restart
until the voltage is normal.
Press the Stop button, fill with water,
wait 3 minutes and press the start
button to restart. When the water has
reached the fill line the ice maker will
restart automatically.
Replace fuse / Switch power on
Stop the machine and reset the
ice-making cycle. Restart the machine
after switching it off.
Call for service.
Clear the ice cube under the ice shovel.
Pull out the plug and insert it again then
press the "START" button. Wait 2
minutes and the machine will restart
automatically.