General Cleaning
Bristan products are made from
premium materials, with hand polishing
and electroplated finishes.
Your shower kit should be regularly
cleaned with warm water, a mild
pH-neutral liquid soap, and polished
with a soft cloth. Any residues from
soap, toothpaste, shampoos and
shower gels can cause blemishes if
not rinsed off straight after use.
Maintenance
Cartridge Cleaning
To clean the cartridge, follow
the steps below:
1. Isolate the hot and cold water
supplies. Remove the anti-tamper
cover (1).
Note: If you have purchased the
MT503CP-ISO or MT503CP-ISOELB,
simply turn the screws in the
isolation assemblies to isolate the
water supplies.
2. Unscrew the head assembly (2/3)
from the body (12/15) using a
suitable spanner.
IMPORTANT: Note the position of
the Adjusting Screw (2/24) before
removing. It will need to be replaced
in the same position in order to
maintain the current maximum
temperature.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Household bleaches and cleaners
contain harsh chemicals and may
damage the surface finish. Avoid using
abrasive cloths, scouring pads, scrub
sponges, steel wool or anything similar.
3. Remove the thermostat (10/17/18),
piston assembly (11/13), thermostat
housing (9/16/19) and return spring
(11/12/14).
4. Soak all components in a suitable
solution until fully de-scaled. Check
all seals and O-Rings for damage
and replace if necessary.
5. Re-grease parts using a WRAS
Approved grease and reverse the
steps to re-assemble the valve.
6. Turn on the water supply and check
all joints and connections for any
leaks.
7. Follow the Temperature Adjustment
process to check and re-calibrate
the maximum temperature.