Majestic fireplaces UVHK23MP Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 8

Gazlı Isıtıcı Majestic fireplaces UVHK23MP için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. Majestic fireplaces UVHK23MP 20 sayfaları. Vermont castings gas log heaters installation and operating instructions

WARNING: Air openings that provide fresh air from an adjoining unconfined space shall not be blocked
or obstructed in any way. Installation of unit should allow a minimum of 2" clearance from any part of the
heater to any of the ventilation openings.
Fig. 2 Ventilation options for confined space.
8
L
W
D
T104
Fig. 1 Minimum flue diameter and flue damper positions.
T104
flue damper
10/27/03 djt
Option 1
- Vents to
Adjoining
Room
Flue Damper Closed for Unvented
Operation and Maximum Heat
Output
Flue Damper Locked Open
to a Minimum Venting Area
of 34 sq. in. (for areas where
unvented products are not
permitted)
NOTE: For round flue opening
minimum flue diameter (D) - 7".
For square or rectangular flue
opening, length x width (L x W)
must equal 30 sq. in.
Option 3 -
Vents to
Adjoining
Room
Option 2 -
Remove Door
to Adjoining
Room
vent370-2
Ventilation options
3/26/99 djt
12"
12"
VO370-2
20008056