Majestic fireplaces Al Fresco ODGSR36A Ev Sahibinin Kurulum ve Kullanım Kılavuzu - Sayfa 14

Dış Mekan Şömine Majestic fireplaces Al Fresco ODGSR36A için çevrimiçi göz atın veya pdf Ev Sahibinin Kurulum ve Kullanım Kılavuzu indirin. Majestic fireplaces Al Fresco ODGSR36A 20 sayfaları. Outdoor gas fireplace

Majestic fireplaces Al Fresco ODGSR36A Ev Sahibinin Kurulum ve Kullanım Kılavuzu
ODGSR Series Outdoor Gas Fireplace
Nova SIT 820 Standing Pilot
14

Troubleshooting

START
Gas Supply On
YES
Pilot Lights with
Piezo Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights Main
Burner
YES
System OK
FP396
NVC-standing pilot troubleshooting
5/6/98
CHECK
Supply Line Hooked up
NO
Shutoff Valve Open
Lockout has engaged. Wait 60
seconds and try again.
Piezo not tight enough for good
ground.
For spark at electrode while
NO
depressing Piezo (Red Button)
1/8" gap to pilot hood needed.
All wiring connections
Replace Piezo Ignitor
Thermodisk
For Air in the lines
Thermopile needs a minimum
325mV. Adjust pilot flame height.
All wiring connections
Replace Thermopile
NO
Thermocouple needs a minimum
of 14mV.
Defective valve. Turn to pilot,
meter should read greater than
100mV.
Thermodisk
Wall switch is not turned on.
Watch for grounded wires!
NO
Thermopile needs a minimum
325mV
Plugged burner orifice
Doors not fully open (Fig. 10)
FP396
20007114