8.8 Flame extinction during operation
If during the firing phase flame appears and then disappears, the control unit will continue normal
operation for next 4 minutes (till transition phase PP4) or 15 seconds (from transition phase PP4 to set
programme – provided it is not less than P4) to recover the flame. If the flame does not appear, control
unit goes back to the firing phase without pellet feeding until the flame is developed or, if flame does
not appear in the safety time of 12 minutes, till error E2 appears.
If flame disappears during operation under set programme, after 15 seconds without flame the control
unit goes to extinction phase and sent message on E6 error.

8.9 Power supply interruption

If power supply is interrupted while the burner is working (what can also occur because of opening the
lower boiler door while the burner is working), after supply is re-established, On, 230 and T
appear
boiler
alternately in the upper display, and current time appears in the lower display, to indicate that the
burner restarts after power supply is re-established. After power supply is re-established, the burner
performs firing without pellet feeding (regardless flame is present or not, lasts 12 minutes) and then
goes to extinction phase and On, 230 T
appear alternately in the upper display and OFF appears
boiler
in the lower display (regardless whether it should work or not). If, after completion of extinction phase,
the burner should work, it goes to normal firing phase and, if the burner need not to work anymore,
OFF appears in the upper display and current time and T
appears in the lower display.
boiler
If, during the next burner start up, error E2 or E6 occur within time before the burner reaches the set
programme, Err will be displayed in the upper display and E230 will be displayed in the lower display
indicating that error could be caused by power supply interruption.
If the main switch turns off (or power supply is interrupted), during operation, the burner will, after main
switch is turned on again, continue to operate under regime as in case of power supply interruption.
8.10. Operation of the regulation in OFF mode / boiler firing with solid fuel - not used for
EKO-CK P boilers
Case a)
New models of boilers (doors can be rearranged to burn solid fuel or pellets)
Rearrange lower boiler door in reverse order from that described in the technical manual (EKO CK P/
CKB P p.8) so that the door be converted to burn solid fuel, or buy additional door for combustion of
solid fuels. The door mounted on the boiler and install the regulator drafts.
Case b)
Old models of boilers (must be installed doors for solid fuel combustion)
Remove the lower pellet door and pellet burner CPPL CPDV door and mount the lower door for solid
fuel and install the regulator drafts.
When you have prepared the door, connect in the 6 - poles regulation connector which is unplug from
the pellet burner (4 - poles regulation connector of the burner do not connect). Reverse the lid of the
micro switch so You disable the operation of the micro switch (see next picture). Boiler regulation is
obligatory to be switch on, on the main switch. On the upper display is shown "OFF" and on the lower
is alternate the time and boiler temperature. In this operation time of the boiler regulation (if the
antifreeze program in not switch on) the room thermostat is not active and the heating and sanitary
water pump (if the sanitary water program parameter is switch on in the program Pr02 and the sensor
for sanitary water is inserted) are switch on at the 68°C, and switch off at 66°C. If the regulation is not
switch on (main switch on "0") the heating pump and sanitary water pump (if we have it) will not be in
operation.
15