decina SANTAI Kurulum ve Kullanım Kılavuzu - Sayfa 4

Sıcak Küvet decina SANTAI için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. decina SANTAI 8 sayfaları.

decina SANTAI Kurulum ve Kullanım Kılavuzu
SPA BATH INSTALLATION
3
Once your spa bath is in place it is important to install the spa pump in the desired, optimum position. When determining the Spa
Pump Position you must ensure there is adequate ventilation & access for pump maintenance.
PUMP INSTALLATION - THERE ARE 2 TYPES OF PUMP INSTALLATION
3
EXTERNAL SPA PUMP
You must penetrate the outside wall to accommodate the pipe work to the pump.
When penetrating the wall, cover the pipe work with duct tape to prevent debris entering the pipework & blocking the jets
when the spa pump is turned on.
The pipe work has been plumbed according to a set height which allows the pump to drain into the bath after use.
Support the pump with a timber, masonry or manufactured pump bracket (available from Decina).
Locate the pump no further than 2 metres from the spa bath and position at the correct height. Keep directional changes
to a minimum and use 2 x 45 degree (90 degrees) bends were possible. Use 40mm UPVC Pressure Pipe for plumbing
installations.
For pumps located outside to protect it from the weather ensure it is covered with a spa pump cover available from Decina.
INTERNAL SPA PUMP
For under hob installation an access panel for ventilation & servicing is required of at least 500mm x 500mm.
A suitable drain tray (available from Decina) should be installed to avoid water damage to property should any leaks occur
from pipe work, connections or normal wear.
For pumps installed inside a two story house, water proofing is advised.
CORRECT
PUMP INSTALLATION
Min. water level 50mm above spa jets
Return line min. 1:36 gradient (1.5°)
Suction line min. 1:36 gradient (1.5°)
STANDARD INSTALLATION
Return line min. 1:36 gradient (1.5°)
Suction line min. 1:36 gradient (1.5°)
TOP OUTLET INSTALLATION
Return line min. 1:36 gradient (1.5°)
Suction line min. 1:36 gradient (1.5°)
TRIFLO INSTALLATION
Spa jets
Suction
- NOTE the Air Bleed won't activate
INCORRECT
PUMP INSTALLATION
PUMP MOUNTED TO LOW
- pump can't drain
PUMP MOUNTED TO HIGH
- pump can't prime, pump will air lock
INCORRECT PIPEWORK LOOP
- pump can't prime, pump will air lock