Electrical requirements

If codes permit and a separate ground wire is
used, it is recommended that a qualified
electrician determine that the ground path is
adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you are
not sure the cooktop is properly grounded.
Do Not have a fuse in the neutral or ground
circuit.
IMPORTANT:
Save Installation Instructions for electrical
inspector's use.
A.
A three-wire or four-wire, single phase,
240-volt, 60-Hz, AC-only electrical supply is
required on a separate, 40-ampere circuit, (Note:
The KECC051 series requires a 20-ampere
circuit), fused on both sides of the line. A time-
delay fuse or circuit breaker is recommended.
The fuse size must not exceed the circuit rating
of the appliance specified on the model/serial
rating plate located on the bottom of the cooktop.
B.
THE COOKTOP MUST BE
CONNECTED WITH COPPER WIRE ONLY.
C.
Wire sizes and connections must conform
to the requirements of the National Electrical
Code ANSI/NFPA 70 – latest edition **, or CSA
Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No. 0-M91 - latest edition ***
and all local codes and ordinances.
D.
The cooktop should be connected directly
to the fused disconnect or circuit breaker box
through flexible, armored or non-metallic
sheathed, copper cable. The flexible, armored
cable extending from the fuse box or circuit
breaker box should be connected directly to the
junction box.
E.
Locate the junction box to allow as much
slack as possible between the junction box and
the cooktop so that the cooktop can be moved if
servicing is ever necessary. Do Not cut the
conduit.
F.
A U.L.- or C.S.A.-listed conduit connector
must be provided at each end of the power
supply cable (at the cooktop and at the junction
box).
Copies of the standards listed may be obtained from:
** National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
*** Canadian Standard Association
178 Rexdale Boulevard
Etobicoke (Toronto), Ontario M9W 1R3

Electrical connection

For model KECC051 series only:
WARNING
Electrical Shock Hazard
Turn power supply off before connecting
wires.
Use 12-gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This cooktop must be connected to a
grounded, metallic permanent wiring system or
a ground connector should be connected to the
ground terminal or wire lead on the cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through the
U.L.- or C.S.A.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
Panel B
For all models except KECC051 series:
WARNING
Electrical Shock Hazard
Turn power supply off before connecting
wires.
Use 8-gauge solid copper wire.
Electrically ground cooktop.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This cooktop must be connected to a
grounded, metallic permanent wiring system
or a ground connector should be connected
to the ground terminal or wire lead on the
cooktop.
This cooktop is manufactured with a frame
connected, green or bare ground wire. Connect
the cooktop cable to the junction box through the
U.L.- or C.S.A.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
For all cooktop models with three-
wire cable from the cooktop:
A.
Where local codes Do Not permit
connecting the frame-ground conductor to
the neutral (white) junction box wire. (Used
for Canadian installations):
4-wire cable from power supply
red wires
bare or green
ground wires
U.L.- or C.S.A.- listed
conduit connector
3-wire cable from cooktop
Ungrounded neutral
Figure 1
1. Disconnect power supply.
2. Connect the flexible, armored cable from the
cooktop to the junction box using a U.L.- or
C.S.A.-listed conduit connector. Tighten screws
on conduit connector.
3. Connect the two black wires together; then
connect the two red wires together using twist-
on connector. (See Figure 1.)
4. Connect the green or bare ground wire from
the cooktop cable to the grounded wire in the
junction box or other grounded connector
using twist-on connector.
5. Put a twist-on connector on end of white wire.
Do Not connect bare ground wire to neutral
(white) wire in junction box.
B.
Where local codes permit connecting
the frame-ground conductor to the neutral
(white) junction box wire. (Not used for
Canadian installations):
3-wire cable from power supply
red wires
white wire
bare ground wire
U.L.- or C.S.A.- listed
3-wire cable from cooktop
conduit connector
Grounded neutral
Figure 2
1. Follow steps 1 and 2 from "A" above.
2. Connect the bare cooktop wire with the white
wire; the two red wires together; and the two
black wires together using twist-on connectors.
(See Figure 2.)
For all cooktop models with four-wire
cable from the cooktop. (These
cooktops are manufactured with white
(neutral) power supply wire and a
cabinet-connected bare ground wire
factory-crimped together.):
A.
Where local codes Do Not permit
connecting the frame-ground conductor to
the neutral (white) junction box wire: (Used
for Canadian installations):
4-wire cable from power supply
red wires
bare or green
wires
4-wire cable from cooktop
1. Disconnect power supply.
2. Connect the flexible, armored cable from the
cooktop to the junction box using a U.L.- or
C.S.A.-listed conduit connector. Tighten screws
on conduit connector.
3. Connect the two black wires together; then
connect the two red wires together using twist-
on connectors. (See Figure 3.)
4. Separate the factory-crimped bare and white
cooktop cable wires.
5. Connect the two white wires together using
junction box
twist-on connectors.
6. Connect the bare ground wire from the
cooktop cable to the grounded wire in the
white wire
junction box or other grounded connector
using twist-on connector. (See Figure 3.)
Do Not connect bare ground wire to neutral
twist-on
connector
(white) wire in junction box.
B.
black wires
Where local codes permit connecting
the frame-ground conductor to the neutral
(white) junction box wire. (Not used for
Canadian installations):
junction
box
red
wires
white
wire
white and bare
grounding oven cable
wires — factory crimped
4-wire cable from cooktop
1. Follow steps 1 and 2 from "A" above.
2. Connect the two black wires together; the two
red wires together; and the factory-crimped
bare and white cooktop cable wires to the
white (neutral) wire in the junction box using
twist-on connectors. (See Figure 4.)
junction box
C.
Where local codes Do Not permit
twist-on
connectors
connecting the frame-ground conductor to
the neutral (white) junction box wire:
1. Follow steps 1 and 2 from "A" above.
2. Connect the two black wires together and the
black wires
two red wires together.
3. Separate the factory-crimped bare and white
cooktop cable wires.
4. Connect the two white wires together using
twist-on connectors.
5. Connect the bare ground wire from the
cooktop cable to a grounded wire in the
junction box or other grounded connector
using twist-on connector. (See Figure 3.)
Do Not connect bare ground wire to neutral
(white) wire in junction box.
junction box
white wires
twist-on
connector
black wires
U.L.- or C.S.A.- listed
conduit connector
Ungrounded neutral
Figure 3
3-wire cable from
power supply
black
wires
U.L.- or C.S.A.- listed
conduit connector
Grounded neutral
Figure 4