Güvenlik Sistemi AFRISO VA-ALERT W için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. AFRISO VA-ALERT W 8 sayfaları. Full tank alarm for sewage tanks

Function Description

VA Alert W sewage tanks is a wireless alarm for
(closed) sewage tanks. The system consists of
a receiver unit for indoor as well as a battery-
powered transmitter module (VA Alert W / T)
sensor for placement under the cap to the tank.
This unit has an estimated run time of approx-
imately 12 months. The central unit has built-in
relay which enables connection to eg alarm
lamp or SMS alert.
VA Alert W is for cisterns / tanks containing
electrically conductive fluids. Full Tank Alarm
is given when the tank content have reached to
the two electrodes at the VA probe's lower part.
The transmitter unit is battery powered and
powered by 2 AA batteries. The unit has built-in
warning of low battery voltage which warns in
good time before the battery is depleted (about
2-3 months before).
!
Safety /
important to consider
• Carefully read the installation manual
before assembly
• The alarm apparatus may only be installed in
dry indoor spaces.
• The equipment may only be used for indica-
tion of high level alarm in the sewage tanks or
water tanks.
• Not to be used in conjunction with oil
or petrol!
• If the idea is to be buried, ensure that the
sensor can be accessed simply by mounting
a manhole, etc.
• The sensor has a standard 2 m cable.
Longer needed should the sensor cable
extended by Cable: RKK 2 x 0.75 mm2.
Use not multicore cable (for pump control
signals or the like).
Subject to design modifications.
AFRISO EMA AB • Kilvägen 2, 232 37 Arlöv, Sweden • Tel +46-40-92 20 50 • [email protected] • www.afriso.se
2
Full Tank Alarm for sewage tanks • Installation instructions
Components parts
VA-ALERT W
VA-probe with a transmitter module
Alarm unit must not be disposed
with household garbage, but should
be handled as electronic waste.
VA-ALERT W