IV Operation
Before turning the power on, ensure that the connection recommendations described above have been followed,
and that the amplifier levels and input/output level potentiometers have been set to zero.
 The PA COM 13X5 can now be switched on and the 24V battery connected if needed (Displayed by
POWER LED (7) on front panel). The amplifiers and sources can also be turned on.
 Gradually turn up the amplifier volumes to ¾ of their range.
 Gradually turn up the volume of the 5 area outputs (35) to ¾ of their range.
 Adjust the master level (4) to 50% and bass and treble to the middle.
 Once the sources are connected and operating correctly, gradually increase the potentiometer (19) of the
source selected using the switches (3) on the front panel until the desired listening level is reached (Selection
is displayed by an LED).
 Adjust the source tone with the trim potentiometer (5).
 Select a broadcast area on the first desk.
 Press and hold the call button. The busy LEDs on all the microphones are lit. The music is cut in the selected
areas. The chime starts (unless it was configured not to be used).
 Adjust the chime level with the trim potentiometer (16).
 Adjust the microphone level as required during message broadcast by turning the potentiometer (14).
 Adjust the tone with the trim potentiometers (15).
 Release the call button: the music is back.
The receiver is turned on and connected to the socket (22):
 Adjust the input level according to the receiver with the trim potentiometer (23) (receiver output 0 dB or - 60
dB).
 Choose the broadcast areas for event 1 with the switches (8)
 If the receiver has a squelch command with Normally Opened dry contact connected to the socket (26),
configure in "ext rem" on the button (27)
 Otherwise, configure the automatic remote control (27) to "int rem". The message detection is set by the
level sensitivity (24) and the recovery time (25).
 Adjust the level with the potentiometer (9). The modulation is displayed on an LED « signal » above this
potentiometer (9) (resp. 12) in addition to the remote.
 Adjust the tone with the trim potentiometer (10) (resp 13).
When the emergency reader (LN4M for example) is correctly connected to the socket (31), the operation is
started by a dry contact (NO) on the terminal "SECURITY REMOTE" "TEL IN" (33).
The safety reader has the highest priority over all other modulation and is broadcast in a general call.
Adjust the level with the trim potentiometer (17). A red LED displays the broadcast of the emergency message.
Each area can be independently adjusted with the trim potentiometers (35). This allows level adjustment
according to each area.
Services techniques et commerciaux : 56, chemin de la Flambère - 31300 TOULOUSE (France) • Tel. +33 (0)5 61 31 86 87 • Fax. +33 (0)5 61 31 87 73
Siège Social : RN 307 - 78810 FEUCHEROLLES • S.A. Capital 80.000 € • SIRET 334 579 869 000 28 • NAF 4652 Z • TVA Intracommunautaire FR 12334579869
MAJORCOM \ QUALITE \ ENREGISTREMENT DES DOCUMENTS \ ADMINISTRATIF \ ENR-12-PEM-V02
User Manual
www.majorcom.fr • [email protected]
1) Music Sources:
2) Microphone Decks:
3) H.F. 1 (resp. 2) Event Podium:
4) Emergency Message Reader:
5) Adjusting the Output level: