CLEANING & MAINTENANCE
The DB T Model 4's are precision machines. It is essential that they be operated and maintained with this in mind. It's important to inspect the machine at initial start-up and after each use
to ensure that no damage or plant material build-up has occurred and that the tumbler spins freely.
In addition, it is highly recommended to clean the machine after every day of use. This ensures that the Blade Sheet and Tumbler are kept lubricated and that resin does not build-up and
affect performance. This is especially important if the machine has been stored for an extended period of time.
CLEANING
Remove Tumbler and Blade sheet and cover with a thick coat of cooking oil (olive, vegetable, etc.). Let sit for 3-12 hours.
scrubber, clean the Tumbler and other machine components by hand.
machine for 15 minute to allow components to dry.
Read full CLEANING AND MAINTENANCE instructions before cleaning.
When to Clean:
Depending on the material being processed and the frequency of use, the slots of the Tumbler may need to be cleaned after each use or periodically.
Indications that machine requires cleaning
• Reduced trim quality
• Visible build-up of material in the Tumbler slots which obscure the sharp edge of the slots
• Visible evidence of material on Blade Sheet
• Excessive noise (machine should run quietly so that you may converse normally when it is running)
REMOVING OBSTRUCTIONS
If the rotating Tumbler becomes restricted or clogged:
Stop the motor and Make sure that all rotating parts have come to a complete stop. Disconnect the trimmer's power cord. Use a wooden stick to clear the obstruction.
INTERVAL
Check that Blade Sheet is snug, and in contact with Tumbler and is tightened appropriately
Before each use
Check that machine is free of excessive debris.
Ensure that machine is clean and the Tumbler can be rotated without power under manual force.
During use
Although not required, application of a food grade lubricant to Tumbler and Blade Sheet can help reduce resin build up.
After each use
For best performance and longevity, clean trimmer after every use or if plant material is visibly affecting the trim quality or speed of the trimmer.
Every 10 hours
To maximize Blade Sheet life, rotate orientation of blade sheet every 10 hours or when visible signs of wear are identified. Although not required, this will extend the life of
of operation
the Blade Sheet.
PRESSURE WASHING THE DBT MODEL 4
NOTICE:
Side Drive is NOT waterproof DO NOT GET WET. If you choose to
use a pressure washer take care not to damage the trimmer's fin-
ish by holding the nozzle excessively close to the machine. Avoid
spraying the bearings, located at the ends of the brush. These
components are not intended to be waterproof and water dam-
age is excluded from warranty coverage.
- Clean with pressure-washer at up to 1500 psi.
- Hot water, fan spray setting.
- Run for 15 mins after washing to allow components to dry.
WARNING:
PINCH POINT HAZARD - WEAR GLOVES WHEN REMOVING BRUSH.
ALWAYS WEAR PERSONAL PROTECTIVE EQUIPMENT WHEN CLEANING MACHINE.
For more information or to watch our DIY video tutorials visit cprosolutions.com
Alternatively you can pressure wash with hot water, at up to 1500 psi on fan spray setting. After pressure washing, run
ITEM
STEP 1:
CLEAN
BRUSH
Simply pull on brush
to remove. Clean the
length of the brush of
all debris using hot
pressurized water.
OWNERS MANUAL
Using warm/hot water, concentrated dish soap and a non-metallic dish
STEP 2:
CLEAN
ELECTROPLISH
TUMBLER
Clean the length of
the tumbler of all
debris using hot
pressurized water.
MODEL 4 DBT
9