8
Make Sure Potentiostat Has Been Detected by
Windows
Because you installed the Gamry software before you
installed the potentiostat, the potentiostat should be
recognized automatically, and the correct software drivers
installed.
To check hardware detection:
1)
2)
3)
Completing Software Setup
Assign Label (Name) to Potentiostat
The potentiostat's Device Settings window opens
automatically the first time the PC is started after the
Framework software has been installed successfully. This
window shows the model number of the potentiostat, followed
by its serial number.
Use this window to specify the text label that will be used to
identify the potentiostat on Gamry software screens. The
maximum size of a label is ten characters (including spaces).
To assign a name to a potentiostat, type the name in the
Label field in the Device Settings window.
Do not click on Finish. You must enter Authorization Codes
as described below.
Gamry Instruments, Inc. © 2008
With the Gamry CD still in the drive, turn on the PC.
After the operating system starts, you will see a
message that an instrument from the Reference Family
Instrument has been detected.
If running Windows Vista, the "Found New Hardware"
screen appears. Select "Locate and install driver
software". You may then need to acknowledge a
security prompt on the next screen.
If running Windows XP, the "Found New Hardware
Wizard" asks questions about the software installation.
When asked about connecting to the Internet, select
"No". When asked about searching the computer to load
drivers automatically, select "Yes". After working
through the wizard, go to the next step.
If the Reference Family of instruments was detected,
remove the Gamry CD from the drive.
or
If you see a message that refers only to "USB Device",
the operating system could not find the Gamry drivers.
Try this: Unplug the USB cable connecting the
Reference 3000, shut down Windows and turn off the
PC. Power up the PC and wait until Windows has
completed normal startup. Shut down Windows and turn
off the PC. Reinsert the USB cable. Power up the PC.
988-00008