Green Energy GECI Kullanıcı Kılavuzu - Sayfa 12
Akü Şarj Cihazı Green Energy GECI için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Green Energy GECI 15 sayfaları. Black diamond charger
CHARGE TERMINATION CODES
GROUP 1: CHARGE COMPLETED
00 Battery modules recognized. Start charging.
01 Charge completed successfully.
02 Charge completed successfully.
Equalize NOT executed because battery was disconnected.
03 Charge completed successfully.
Equalize started but not completed, because battery was disconnected during the cool-down time before the Equalize cycle.
04 Charge completed successfully.
Equalize started but not completed, because battery was disconnected while the Equalize was in progress.
05 Charge completed successfully. Over range maximum time during pulsed
06 Desulphation cycle completed successfully.
07 Charge completed successfully. Equalize completed successfully.
Refresh-Cycle NOT executed because battery was disconnected.
08 Charge completed successfully. Equalize completed successfully.
Refresh-Cycle started but not completed, because battery was disconnected while the Refresh was in progress.
09 Charge completed successfully. Equalize completed successfully.
Refresh-Cycle completed successfully.
10 Gassing voltage reached successfully.
Full charge NOT executed because time window Disabled.
12 Charge completed successfully. Equalize completed successfully.
GROUP 2: MANUAL STOP
11
Charge stopped manually, during a generic cooling state
20 Charge stopped manually, before to reach the gassing voltage.
21 Charge stopped manually, during the finishing charge.
22 Charge stopped manually, during eq.
23 Charge stopped manually, during refresh.
24 Charge stopped manually, during desulphation.