Gantner 631325 Manuel - Sayfa 5

Kilitler Gantner 631325 için çevrimiçi göz atın veya pdf Manuel indirin. Gantner 631325 7 sayfaları. Battery powered mifare and iso 15693 lock

Gantner 631325 Manuel
Installation requirements for GAT ECO.Side Lock 7000 and bolt set
Please pay particular attention to the following points:
- The thickness of the locker door must be between 18 and 26 mm
(0.71´´ and 1.02´´).
- When the locker door is pressed shut, ensure there is no gap between
the bolt set (2) and the front of the GAT ECO.Side Lock 7000. Ideally
the bolt set should touch the front of the lock.
- The front side of the bolt set and the GAT ECO.Side Lock 7000 must be
aligned parallel to each other.
Installation procedure
Note: Before installing all locks in a new locker system, a test installation
of at least one lock and a final function check must be performed.
Only once the functional testing is successfully completed may the
remaining locks be installed in the same way.
Locker door
(Front view without label carrier)
1. Drill 3 holes (3) for the GAT ECO.Side Lock 7000 into the locker wall.
2. Insert the batteries into the GAT ECO.Side Lock 7000 (see page 7).
3. Mount the GAT ECO.Side Lock 7000 with 3 screws (3) on the inside
locker wall.
1
6
Attention: Use the correct screws according to the type of locker
material, max. Ø 4 mm (0.16´´). The maximum allowed
tightening torque of the screws is 2 Nm (1.47 lb-ft).
4. Cut-out a section, 62.6 mm x 68 mm (2.46´´ x 2.68´´), in the inner wall
2
of the locker door for the GAT NET.Lock Bolt Set 7200.
5. Drill 4 holes (6) in the inner wall of the locker door for mounting the
GAT NET.Lock Bolt Set 7200.
7
6. Cut-out a section, 67.6 mm x 93.6 mm (2.66´´ x 3.68´´), in the outer
wall of the locker door for the label carrier.
7.
Mount the bolt set onto the inside wall of the locker door using 4
screws.
Attention: Use pan-head metal screws, Ø 3.5 mm (0.14´´), screw
length depends on locker door thickness. The maximum
6
tightening torque of the screws is 2 Nm (1.47 lb-ft).
8. Push the label carrier onto the outside wall of the locker door. The
label carrier will hold in place with the lashes on the label carrier. To
15.1 mm (0.59´´)
protect against manipulation, a screw can be used to fix the bolt set to
the label carrier.
Attention: Use a countersunk screw, Ø 2.9 mm (0.11´´). Screw length
depends on locker door thickness, e.g., a 15 mm (0.59´´)
thick door requires a 19 mm (0.75´´) long screw.
www.gantner.com
Locker door
(Front view with label carrier)
10
7
Valid from June 10th, 2015 • Technical data subject to modification without notice!
9. Attach the front label (11) onto the label carrier.
Attention: If a custom label design is used, ensure that a transparent
field for the status LED (7) is included in the label design.
(Front view with label carrier)
123
7
10. Test the locker door to confirm that it can close easily and the door
shackle inserts correctly into the GAT ECO.Side Lock 7000.
DB_GAT-ECOSide-Lock7000--EN_11.indd • Part No. 642832
Locker door
11
5