OPERATING SPECIFICATION
I.
KEY SPECIFICATION:
1. The "RES" has two functions for the actual operation:
(1) On / Off: The system can be started up by pressing it for more than ls and shut down by pressing it for more
than 3s.
(2) Reset: The system can be reset by pressing it for 0.5 ~ 3s at any interface.
2. The "SEL" has two functions for the actual operation:
(1) Selection: For example, when the sensitivity is adjusted, all locations can be switched;
(2) Digit switching: For example, when the password is entered, different digits can be switched.
3. The "ADJ" has two functions for the actual operation:
(1) Number modification: For example, when the password is entered, the numbers can be modified;
(2) Digit switching: For example, when the sensitivity is adjusted, the sensitivity digits can be switched.
4. The "ENT" has three functions for the actual operation:
(1) Confirmation: When a menu is selected and confirmed, the password input interface of the secondary inter
face can be shown if the key of the main interface is pressed after startup.
(2) Setting savin g: The modified menu or parameter can be saved.
(3) Number modification: When the sensitivity and alarm are set, the numbers can be modified.
II. BASIC OPERATION
1. Startup:
The system under the shutdown mode can be started by pressing "RES" for more than ls. The system
performs the signal self-inspection during the startup. If the inspection meets the requirement, a "0" will be
shown, if the inspection fails to meet the requirement, an "E" will be shown. After the inspection finishes and the
frequency setting is OK, the main interface will be shown as in Fig. 1:
2. Shutdown:
The system under the operating mode can be shut down after "RES" has been pressed for more than
3s and the ring has been triggered.
3. Reset:
Under the operating mode, the system can be reset by pressing "RES" at any interface for 0.5 - 3s, and
at this time the interface will go back to the initial one as shown when the machine is started and the number of
passed persons and alarms will be reset.
Fig. 1
www.2MTechnology.net
2M Technolgy User Manual
9