Fault: Pump runs all the time.
1. Is the float position with the magnet uppermost?
2. Is the reservoir lid (sensor) located firmly onto the reservoir, with the
float located inside the reservoir, around the sensor column?
3. Is there sludge inside the reservoir, preventing float from resting on
the bottom? (This may occur if the pump has been in operation for
some without cleaning. Clean using an anti-bacterial wash.)
Please note:
• After installation and during operation, if you notice air
in the pipe between the reservoir and the pump, you
have a siphoning problem (Fit an Anti Siphoning Device
following step 10 on page 10).
• The pump will only switch off when the float is at the
bottom of the reservoir.
13
Fault: Pump stops and starts and makes a loud noise.
1. The water is siphoning through the pump. Fit an Anti Siphoning
Device following step 10 on page 10.
Fault: Pump runs but does not pump any water.
1. Are there any air leaks in the pipe running to the pump?
2. Check that reservoir, filter and inlet tube are free of sludge and
debris.
Fault: Pump isn't operating at all.
1. Is power reaching the pump? Is it correctly wired? Is the
voltage correct?
2. Is the pump very hot? A thermal cut0out may have been
activated to protect pump.
This will automatically reset once pump has cooled down.