1
4" minimum
side clearance
from
combustible
Discharge
material*
Nozzle
20˚
EXTERIOR
*Electrically Heated Units Only
For more information see page 4
3
The keyhole slots are spaced 1" from
the ends, and 3/4" and 7" from the top.
Mark the wall according to
the length of the air curtain.
If the keyhole slots are not
located where suitable
support is available,
drill new holes in
the back plate
where space
is available.
For more information see page 5
5
To use threaded
Suspension Rods
rod to hang from
the ceiling
instead of
the wall - use
the factory
installed
1/4" Threaded Insert
threaded inserts.
For more information see page 6
®
4" minimum*
AIR
Before hanging,
check to see what
the clearance is
above the door.
6' minimum*
INTERIOR
7"
Keyhole
Mounting
Slots
Side View
Berner International
www.berner.com
111 Progress Ave. / New Castle / PA / 16101 / USA
Simple to Install
Easy to operate & maintain
2
Flush Mounting
AIR
CURTAIN
1"
Top of Doorway
Rule of thumb – If the unit must be mounted
higher than 1" above the opening, it must be
spaced out from the wall 3/8" for every inch the
unit is above the door opening.
For more information see page 4
4
Push
Backplate
1/4"
Toward Wall
Line-up
Keyholes on
All Screws
After installing the mounting hardware, lift and
slip the air curtain over the mounting hardware by
grasping the inlet rings. Tighten the mounting
hardware.
For more information see page 5
6
To wire – follow the wiring diagram (found inside
wiring compartment).
The controls ship in the same box as the air curtain.
For more information see page 7
800.245.4455
3
Spacer
Seal
AIR
CURTAIN
Spacer
3"
2"
3/8"
3/4"
Tighten All
Screws
Slide
Backplate
Down