E rr
I ncline cannot reach the right position, incline function cannot be use but other
】 :
2.2.
functions are normal to use.
*If this is a new product that has just finished being assembled, there is a possibility of
problems in assembly. Check the wire connections and confirm that the wires and cables
have not been damaged during assembly.
Determine Cause and Solution:
Showing ERR
Turn OFF the AC power and
wait for 10 seconds and then
turn ON the AC power.
Pull out the safety key, press
STOP and UP to enter the
engineering mode, displays
M ANUAL INC XXX
(XXX=Incline parameter)
Did the incline move while
pressing the incline UP or
DOWN key?
Yes
Did the incline motor move
and the incline parameter
change while pressing the
incline UP and DOWN key.
(Parameter range is from the
lowest to highest position, 15
to 195. Check this value
range.
Yes
Incline motor is good. Press
STOP to go back to idle state.
Remark A: Before installing a new incline motor or Variable Resistor (VR), be sure to have the
incline level set to zero ( 0 ).
www.GreenSeriesFitness.com
Did the D5 or D6 lamps
No
illuminate while pressing the
A
incline UP or DOWN key?
Check the surface
temperature of the incline
motor. Is it hot?
Wait for cool down and then
repeat step A. If the incline
motor does not work after the
cool down, proceed to step B.
No
Incline motor faulty. Replace
the incline motor or the
variable resistor (VR).
(Remark A)
©May 2015
CIR-TM6000DC-G Revision 1.1
No
Yes
Strip the incline
No
motor down to
B
check for
movement
Yes
obstructions or
jamming. If the
incline motor is
good, replace the
motor controller.
Call Toll free (800) 269-7140
Replace the
console PCB
8