Ganz Thermal PT Thermal Series Hızlı Başlangıç Kılavuzu - Sayfa 4

Termal kameralar Ganz Thermal PT Thermal Series için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Ganz Thermal PT Thermal Series 9 sayfaları.

PT Thermal Series Quick Start Guide
2.
Measure approximately 5 inches of cable slack from the end of the
cable to the rubber grommet of the sealing gland. Use a scale to
measure the length.
3.
Attach one open end wrench onto the flange of the cable gland
and tighten the compression nut, with the second open wrench, to
approximately 50-55 in-lbs. of torque
4.
Assemble a new RJ45 head to the Cat 5 Ethernet Cable
Securing for IP66 (Ethernet & AC/DC power):
1.
Slide the Ethernet cable through the threaded end of the cable
sealing gland, with O-Ring installed.
2.
Slide the 2, 20 AWG power wires through the back side of the
cable sealing gland.
3.
Measure approximately 5 inches of cable slack from the end of the
cable to the rubber grommet of the sealing gland. Use a scale to
measure the length.
4.
Attach one open end wrench onto the flange of the cable gland
and tighten the compression nut, with the second open wrench, to
approximately 50-55 in-lbs. of torque.
5.
Assemble a new RJ45 head to the Cat 5 Ethernet Cable.
6.
Assemble a mating power connector to the 2 AC or 2 DC power
cables.
Securing for IP66 (Analog & AC/DC Power)
1.
Slide the Coax cable through the threaded end of the cable sealing
gland, with O-Ring installed.
2.
Slide the 2, 20 AWG power wires (and any RS-485 wires) through
the back side of the cable sealing gland.
3.
Measure approximately 5 inches of cable slack from the end of the
cable to the rubber grommet of the sealing gland for the power
wires and approximately 10 inches of cable slack for the analog
cable. Use a scale to measure the length.
4.
Attach one open end wrench onto the flange of the cable gland
and tighten the compression nut, with the second open wrench, to
approximately 50-55 in-lbs. of torque.
5.
Assemble a new BNC connector to the Coax Cable.
6.
Assemble a mating power connector to the 2 AC or 2 DC power
cables (and RS-485 cables if used).
Securing for IP66 (Analog & Ethernet)
1.
Put the nut onto the cables first. And then push the analog video
cable (RG179BU required for this configuration) and CAT5 cable
through the gland. The CAT5 cable goes through the center. The
analog video goes through one of the 5 outer holes.
4
www.ganzsecurity.com
December 2013