GAPOSA XQ5PR4017 Talimatlar Kılavuzu - Sayfa 5

Motor GAPOSA XQ5PR4017 için çevrimiçi göz atın veya pdf Talimatlar Kılavuzu indirin. GAPOSA XQ5PR4017 8 sayfaları. Tubular motors with mechanical limit switch and integrated receiver

►DESCRIPTION
EN
Tubular motor designed for rolling shutters, blinds and awnings.
It features an integrated receiver (434,15MHz) with remote limit setting
and remote user programmable intermediate stop. It works with
GAPOSA transmitters.
Motor's memory capacity: maximum of 28 transmitters.
Transmitters' range: 20 m indoor and 300 m outdoor.
►INSTALLATION (Fig. 1)
WARNING: Tubular motor must be always installed in the tube first before
putting it into action since the electronic control of the speed variation do
not enable the motor to turn if the limit switch drive do not turn with it.
WARNING: The mounting distance between two motor heads should
not be less than 1/2m;
To complete installation, the motor must be provided with a couple of
adaptors (corresponding with the tube) and a fixing bracket. For a list of the
available accessories, refer to the catalogue.
WARNING: incorrect installation can cause serious injuries. Follow the
installation instructions. Before you remove all unnecessary cables and
turn off any equipment not required for this operation.
• Fix the adaptors to the motor distinguishing the limits ring (Fig. 1.1 A) from
the drive pulley ( (Fig. 1.2 B).
• Turn and lock the clip after inserting it in the drive-shaft groove.
• The fixing bracket (C) must be fixed inside the box or on the awning frame so
that the roller tube (F) is perfectly horizontal and at a height not less than
1,8m.
• Insert the motor (E) into the tube (F) until its end stops against the limits ring.
• Place the motor square pin (D) on the bracket (C) and the cap at the opposite
end of the tube on the fixing plate.
WARNING:
• Never hit on the head of the motor (D) when you insert it into the tube.
• For the 50 range, with torque up to 15Nm, the minimum tube diameter
is 50x1,5mm; for motors with higher torques, the minimum tube
diameter is 60x1,5mm. For the 60 range, the minimum tube diameter is
63x1,5mm.
• The screws used to fix the last slat on the tube may be too long and
reach the tubular part of the motor. Use appropriate screws or fixing
clips.
• Motor moving parts installed under 2,5m from the ground must be
protected.
• A wrong motor installation can damage persons or objects.
►WIRING (Fig. 2)
Check that the mains voltage available on the system is as shown on the label.
The motor mains connection should be executed according to the diagram on
the next page, by qualified technicians able to operate in compliance with the
rules.
ATTENTION:
The power supply must contemplate a switching device with an
opening distance between contacts of at least 3mm.
For models range XQ50 with limit switches without manual override, in case
the supply cable is damaged, it must be replaced by another cable or a special
set available by the manufacturer or his technical assistance (Fig. 3).
►PROGRAMMING THE FIRST TRANSMITTER (Fig. 4)
The first transmitter to be programmed is called MASTER.
It is the only transmitter by means of which You can enter the programming
mode.
NOTE: If the MASTER must be replaced, you have to RESET the memory
of the receiver and then program a new transmitter as MASTER.
1. For initial programming provide power only to the motor being
programmed;
2. Press and hold Prog-TX button of transmitter till the motor starts moving.
3. Check the motor direction (Ex.: UP as shown aside) then releasethe Prog-TX
button and within 5 seconds press the UP button of the transmitter;
4. If, on the contrary, pressing the Prog-TX button the motor turns
DOWNWARDS, release the Prog-TX button and press the DOWN button of
the transmitter within 5 seconds. The MASTER transmitter is now
programmed and the direction of the motor synchronized with the buttons
of the transmitter itself.
Now verify the motor directions (if UP on the transmitter corresponds to UP on
the end-product).
ATTENTION! As long as You press the Prog-TX, the motor turns in a
direction.
Releasing Prog-TX the motor stops, then pressing it again, the motor
turns again in the opposite direction (sequential fashion).
►PROGRAMMING PROCEDURE IN INSTALLATION MADE UP OF
SEVERAL XQ PR [only for XQ50]
If the installation is made up of several XQ-PR, only one PR motor must be
powered during programming. All the other motors must be disconnected in
order to avoid interferences
►SETTING THE END LIMITS
XQ PR limit switches are already set at about 2 turns in both directions.
- Turning the screws anti-clockwise (unscrewing), you increase the roller's
range (the number of revolutions increases).
- Turning the screws clockwise (screwing), you reduce the roller's range (the
number of revolutions decreases).
After installation and before connecting the shutter/awning/screen to the
tube, move the rolling tube downwards (unroll it) till it stops.
ATTENTION! Check the right rotation of the tube
1. Turn anticlockwise the DOWN setting-screw (+) till the tube reaches the
best position in order to enable the connection between tube and shutter/
awning/screen.
2. Fix the shutter to the tube and then turn the DOWN setting-screw
clockwise (-) or anticlockwise (+) in order to find the right position of the
down-limit-switch.
3. Move the shutter/awning/screen upwards till it stops and then turn the UP
settingscrew anticlockwise(+) till the shutter/awning/screen reaches the
up-limit.
4. I n order to modify the up-limit-position when it stops over range, move XQ
down (unroll shutter/awning/screen) a little, then turn the UP setting-screw
clockwise (-).
Repeat the procedure from point 3.
►ADD A TRANSMITTER/CHANNEL IN THE MEMORY OF THE MOTOR
1. Press and hold PROG-TX button of the MASTER transmitter till the motor
starts moving. The motor is now in the programming mode;
2. C heck the motor direction then release the PROG-TX button and press the
UP or DOWN button of the new transmitter within 5 seconds.
In this way you have set the new transmitter in the motor's receiver.
►RESETTING THE MOTOR'S MEMORY
To cancel transmitters from the motor's memory, press PROG-TX and STOP
buttons of the MASTER transmitter simultaneously and release them when
the motor jogs indicating that every transmitter is deleted.
►RESETTING THE MOTOR'S MEMORY WHEN THE MASTER TRANSMITTER
IS LOST
1. Cut the power.
2. P ress first PROG-TX and STOP buttons of any GAPOSA transmitter.
3. Switch-on the power and wait for the motor to jog, indicating that any
transmitter is deleted.
► MANUAL OVERRIDE (Range M) - FIG. 5
Motor with manual override in some installation examples
IMPORTANT:
The motor with manual override must be installed orthogonal to the
fixing plate and in a roller tube perfectly horizontal.
The manual override device on the head of the motor (cardan-joint
with eye or shaft with eye) must be fixed not higher than 1,8m.