GAPOSA QC101 Çalıştırma Talimatları Kılavuzu - Sayfa 5
Kontrol Ünitesi GAPOSA QC101 için çevrimiçi göz atın veya pdf Çalıştırma Talimatları Kılavuzu indirin. GAPOSA QC101 16 sayfaları. Single-phase control unit
POWER
When you activate the board the red LED switches on steadily for about
3 seconds. After about 1 second, the green LED will flash a number of
times equal to the review.
When the red LED switches off, the green LED switches on steadily
indicating that the switch on procedure of the card is completed and now
it is ready for operation.
OPERATING LOGIC
The control unit has 2 operating logic:
1. Automatic: opening and closing are automatic.
2. Dead-man in closing: opening is automatic while closing is dead-man.
The logic of operation is selected using DIP 2 according to the following
table:
OPERATING LOGIC
DIP 2
OFF
Automatic
Dead-man in closing / Automatic in opening
ON
(not for use with QCTRKP)