KPA-2322
3.
Customer Wiring
Step 1:
Locate terminal to be wired and open cover by sliding orange latch towards the hinge and
lifting up. as shown in Figure 2.
Step 2:
Use a sharp object to puncture a small hole through one of the grommets located in the
bottom left and right of the housing as shown in Figure 3.
Step 3:
Pull wire through the hole in the grommet and extend 3 inches past top of box. Route wire to
terminal to be wired. It is not necessary to strip the wires.
Step 4:
Feed the wires through the hinge of the module
door to the first line position on the left of the
module (Figure 4). Or if desired, remove door to
facilitate wire routing.
Step 5:
Press the orange lever toward the "T R" marking
on the module.
Step 6:
Insert the wires into the tip and ring holes and
press the wires into the wire channels.
Step 7:
Pull the orange lever back to the CONNECT
position (away from the "T R" marking). Gently tug
on wires to check connection.
Step 8:
Repeat for other line connections and close the
module door. Slide the latch all the way to the left.
Tuck extra wire in trough of housing.
4.
Testing
Open cover and plug a working telephone into jack. Normal dial tone shows telephone line is working
properly. If dial tone is not heard, close cover and notify repair service.
5.
Customer Lock
A customer lock #10 Master padlock, or equivalent, may be installed on the network interface for
individual security.
STANDARD RECOMMENDED PROCEDURE 203-297 | ISSUE 2 | MAy 2015 | PAGE 2 OF 4
Orange Latch
Figure 2
TPA-5032
KPA-2327