EWS-102 CONTROL UNIT
To begin the system setup
press the
and
buttons together
Enter the system setup menu.
Select the first menu item.
CAP
AL 1
AL 1
AL 2
AL 3
hyst
dLy
diSP
FIL
bEEP
5rES
Multi Analog
version only
OUT
Firmware 5.5 Rev 2 subject to alteration
The system setup menu allows you to set and adjust various parameters
Naviga�on
Use the bu�on to step through the menu items. Press
item
Edi�ng Values
When a value is displayed, use
flashes) and use
Press
The system will revert to the opera�onal display a�er approx. 10 seconds.
Alterna�vely, return to the opera�onal display by pressing
CAL
Notes
1
To calibrate the EWS 102, a link must be fi�ed to the control
signal input terminals. Leave in a�er calibra�on if a control
signal input is not being used.
SYST
2
Un�l a sensor is connected, the EWS will display Err6
preven�ng access to the system setup and calibra�on menus.
3
Calibra�on and set up can be carried out on any floor, but the EWS 102
must be re-zeroed at the lowest floor to finalise the Analog output
calibra�on (mul� analog only)
CAP indicates the elevator maximum capacity. To view the current value press
AL 1 is the load value to trigger Alarm Relay 1. To view the current value press
AL 2 is the load value to trigger Alarm Relay 2. To view the current value press
AL 3 is similar to Alarms 1 & 2 but allows negative values to be entered. When editing the
most significant digit, instead of rolling over from 9 to 0 it included the minus sign option.
Defines the value by which the load in the lift has to drop to reset the instrument,
once the alarm has been triggered.
Defines the time from the control signal input is activated and the car load is stored.
Default =2, the available settings are: 0 = 0sec, 1 = 0.5sec, .....7 = 3.5sec.
Op�on for turning the display on or off when the li� is moving, the door close signal
ac�vates. To change the setting, press
The filter value determines the update rate and damping factor. The available settings are:
0 = 0.4sec, 1 = 0.8sec, 2 = 1.2sec, 3 = 1.6sec.
An internal sounder beeps when an overload alarm is triggered or when the keypad is pressed.
To change the setting, press
Op�on to turn the systems reset func�on on or off. Leave OFF during system set up and zero and
load calibra�on. Select ON a�er calibra�on and before entering the li� into service.
To change the setting, press
Mul� Analog Version only. Select the required Analog output . Refer to page 4 for available outputs
to select the digit to edit (selected digit
to step through the values for that digit.
to save a change.
and use
To toggle between On and OFF.
and use
To toggle beteween On and OFF.
and use
To toggle beteween On and OFF.
SYSTEM SETUP
to view the menu
twice