Avante HED102D Lift Montaj Talimatları - Sayfa 2

İç Mekan Mobilyaları Avante HED102D Lift için çevrimiçi göz atın veya pdf Montaj Talimatları indirin. Avante HED102D Lift 3 sayfaları. Height adjustable office desk

INSTALLATION
3
Install the side plate (3) and use the wrench (E)
to lock the screw (B)
3
B
M6x12
8PCS
E
Insert the connecting rod (7) into the frame (5) .
4
7
5
Adjust the distance according to the size of the table,
and then tighten the screw (B) with the wrench (E).
B
E
M6x12
8PCS
6
Mount the desktop (1) with screws (A) on the two side plates
A
M5x16
8PCS
Mount the control box(10) under desktop(1) with screws (A).
7
Use the screws (D) to install the controller panel(2) under
the desktop (the right or left side of the desk can be chosen
to mount the control box)
A
M5x16 2PCS
D M5x12 2PCS
8
OPERATION
1
3 4
1
2
S
S
Memory
Position
Reset
Protection mode (auto lock screen mode)
Over-heating
protection
Sensorless
alarm
Overload
protection
Rebound
protection
Overvoltage
alarm
Undervoltage
alarm
Step out alarm
Breaking
protection
Metric and
English
unit conversion
Press
and display real height
Press
and display real height
Press
until 1 appears, release the button, it runs
to corresponding height and displays current position.
Press
until 2 appears, release the button, it runs
to corresponding height and displays current position.
Press
until 3 appears, release the button, it runs
to corresponding height and displays current position.
Press
until 4 appears, release the button, it runs
to corresponding height and displays current position.
Save button,used to enter the save height function
After
press , the interface flashes and set memory
S
position, press
until H1 appears, release button and
it displays current height.
in condition of E2 or run to basic height position, long
press
for 5 seconds, display RES and press still, it
goes down to the lowest and rebound certain height,
reset finish and show basic height.
Hot: it alarms when continuous working 2 minutes;
clear automatically after resting 18 minutes.
E1: It alarms when motor hall value cannot be inspected;
clear it after press reset or re-power on.
E2: overload alarm when running up, clear automatically
after 3 seconds; overload alarm when running down,
clear it after press reset or re-power on.
E02: it alarms in reversed compression when running;
clear automatically after rebound 4cm; or press any
button to clear when rebounding.
E03: it alarms when voltage is higher than limit value,
clear automatically after voltage reduced to set value.
E05: it alarms when voltage is lower than limit value;
clear automatically after voltage is higher than set value.
E06: it alarms when height difference between left and
right leg exceeds set value; disconnect power supply for 1
minute to clear error.
It stops and enters protection state when motor lines or
manual control lines are removed or disconnected
accidentally; back to normal after reconnected and alarm
cleared.
Press
S
for 3 seconds and it will display ---, release
S
,
press
until 0 appears, release the button and it
displays current height. (metric unit)
Press
for 3 seconds and it will display ---, release
,
S
S
press
until 1 appears, release the button and it
displays current height. (English unit)