Step 4:
Route the cable and pigtails to an appropriate splicing
surface and perform steps as described in the
instructions for the splice tray and splicing method you
are using.
Step 5:
Once splicing is complete, route cable slack around
the plastic retaining guides inside the storage area and
secure the splice tray into the unit using the retainer
bracket.
10. Cable Routing
Step 1:
Install connectors onto the fibers as per
manufacturing instructions, if nessessary.
Step 2:
Route the fibers inside the housing using the
routing pattern shown, ensuring a minimum
bend radius is maintained.
Step 3:
Clean adapters annd connectors per standard
company practices. Mate connectors in the
adapters.
NOTE: A cable tie and anchor can be used to secure the fibers as
needed.
11. Jumper Installation
Route the jumpers into the unit through either top or bottom holes
in the customer compartment and secure to the strain-relief bracket
using cable ties or the UCC.
12. Door Lock Installation
Step 1:
Remove the double-D knockout from the appropriate door.
Step 2:
Using the locking kit (p/n HDWR-LOCK-KIT), assemble
the components in the orientation shown.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm
Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products
without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other
trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2010, 2015 Corning Optical Communications.
All rights reserved.
STANDARD RECOMMENDED PROCEDURE 003-499 | ISSUE 4 | SEPTEMbER 2015 | PAGE 5 OF 5
TPA-3004
Tie
wrap
anchor
TPA-3001