KitchenAid 9.76E+13 Kurulum Talimatları Kılavuzu - Sayfa 7
Menziller KitchenAid 9.76E+13 için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. KitchenAid 9.76E+13 12 sayfaları. 30" electric freestanding range
Direct wire method: Copper or Aluminum wire
NOTE: The bag containing three
aluminum terminal lugs must be used
when making a direct wire connection.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire, or 6 gauge
aluminum wire.
Electrically ground range.
Failure to follow these instructions can
result in death, fire, or electrical shock.
This range may be connected directly to
the fuse disconnect or circuit breaker box;
or with a U.L.-listed, 40 amp range power
supply cable. Depending on your
electrical supply, make the required
three-wire or four-wire connection.
1. Disconnect power.
2. Remove the knockout as needed for
conduit connection.
3. Assemble a
U.L.-listed
conduit
connector in
opening.
4. Strip outer covering back 3 inches to
expose wires. Strip the insulation back
1 inch from the end of each wire.
3"
1"
5. Allow enough slack in the wire to
easily attach the wiring terminal
block.
6. Use 3/8" nut driver and remove the
outside nuts on the terminal block
screws. Do not loosen the factory-
tightened nuts behind the outside
nuts.
aluminum
lug
7.
IMPORTANT: the aluminum terminal
lugs must be assembled to the
terminal posts with the set screws
facing out as shown.
8. Attach three aluminum terminal lugs
to terminal posts.
Use a 3/8" nut driver and tighten the
nuts securely. Nuts must be
tightened to 20 in/lbs of torque for
proper electrical connection.
9. Complete electrical connection
according to your type electrical
supply ("Four-wire electrical
connection" or "Three-wire electrical
connection. " )
Four-wire electrical connection:
U.L.-listed
conduit
connector
line 1
green
ground
wire
Use this method for new installations,
mobile homes, recreational vehicles and
whenever four-wire installation is
required.
10. Remove the ground-link screw from
the range frame. Save the ground-link
screw and cup washer. Bend up the
ground link so that it does not contact
the range. See Figures 1 and 2.
11. Connect the green ground wire to the
range using the ground-link screw
and cup washer. The ground wire
must be attached first and must not
contact any other terminal. See
Figure 2.
terminal
screw
set screw
must face out
ground
link
ground
screw
Figure 1
slotted
set screw
neutral
(center wire)
line 2
Figure 2
12. Loosen (do not remove) the 3 slotted
set screws. Insert the neutral (white)
wire into the hole at the bottom of
the center position lug (attached to
center terminal screw black terminal
block). See Figure 2.
13. Connect the other two wires (lines 1
and 2) to the outer aluminum lugs.
14. Securely tighten the set screws.
For 8 gauge copper wire, tighten to
25 in/lbs of torque, and for 6 gauge
aluminum wire, tighten to 35 in/lbs of
torque to make a proper electrical
connection. See Figure 2.
15. Tighten the locking ring of the
conduit connector.
16. Replace the terminal block cover.
Three-wire electrical
connection:
line 1
Figure 3
Use this method only if local codes
permit connecting ground conductor to
neutral supply wire.
10. Loosen (do not remove) the 3 slotted
set screws. Insert the neutral (white)
wire into the hole at the bottom of the
center position lug (attached to center
terminal screw of terminal block). See
Figure 3.
11. Connect the other two wires (lines 1
and 2) to the outer aluminum lugs.
12. Securely tighten the set screws.
For 8 gauge copper wire, tighten to
25 in/lbs of torque, and for 6 gauge
aluminum wire, tighten to 35 in/lbs of
torque to make a proper electrical
connection. See Figure 3.
13. Tighten the locking ring of the conduit
connector.
14. Replace the terminal block cover.
slotted
set screw
neutral
(center wire)
line 2
7