KitchenAid Architect II KDRS505XSS Şartname Sayfası - Sayfa 2
Menziller KitchenAid Architect II KDRS505XSS için çevrimiçi göz atın veya pdf Şartname Sayfası indirin. KitchenAid Architect II KDRS505XSS 2 sayfaları. 30" (76.2 cm) double oven dual fuel range
ELECTRICAL REQUIREMENTS (cont.)
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker box
(or fused disconnect) through flexible or nonmetallic sheathed,
copper or aluminum cable. See the "Electrical Connection -
U.S.A. Only" section.
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end of
the power supply cable (at the range and at the junction box).
Wire sizes and connections must conform with the rating of
the range.
The wiring diagram is located on the back of the range or in a
clear plastic bag.
CABINET OPENING DIMENSIONS
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop
height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or microwave
hood combination installation instructions for dimensional clearances
above the cooktop surface.
Range may be installed with zero clearance to combustible
construction at the rear and on the sides below the cooktop.
A. 18" (45.7 cm) upper cabinet to countertop
B. 13" (33.0 cm) upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to the top of the cooktop, see NOTE.
E. 30" (76.2 cm) min. opening width
F. 3" (7.6 cm) min. clearance from both sides of the range to the side
wall or other combustible material.
G. Cabinet door or hinges should not extend into the cutout.
H. 3" (7.6 cm) distance from wall
I. 1 " (3.8 cm) min. from right side cabinet
J. 8" (20.3 cm) width
K. 7" (17.8 cm) min. from floor
L. 2" (5.1 cm) min. from floor
*** Drill on centerline 1 " (3.1 cm) from rear wall for gas supply line.
*** Gas lines must be installed within the shaded area to ensure
proper alignment of this oven with cabinets.
*** Recessed electrical plugs must be installed within the shaded area
to ensure proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet
is covered by not less than
" (0.64 cm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking
platform and the bottom of an uncovered wood or metal cabinet.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Range Rating*
120/240 Volts
120/208 Volts
8.8 - 16.5 KW
7.8 - 12.5 KW
16.6 - 22.5 KW
12.6 - 18.5 KW
** The NEC calculated load is less than the total connected load listed on the
model/serial rating plate.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified Power Cord intended to
be plugged into a standard 14-50R wall receptacle. Be sure the wall receptacle is
within reach of range's final location.
Do not use an extension cord.
A
F
8½"
(21.6 cm)
1½"
(3.8 cm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Rating of Power
Circuit
Supply Cord
Protection
Amps
Amps
40
40 or 50
50
50
D
B
C
E
J
G
I
K
L
H
L
14"
***
(35.6 cm)
2¼" (5.7 cm)
1¼"*
(3.1 cm)
8½" (21.6 cm)**
gas line location
Page 2 of 2
Ref. W10345640B
1/28/11