E-T-A E-1071-623 Manuel - Sayfa 7
Kontrolör E-T-A E-1071-623 için çevrimiçi göz atın veya pdf Manuel indirin. E-T-A E-1071-623 12 sayfaları. Solid state remote power controller
Solid State Remote Power Controller E-1071-
Description
The E-T-A Solid State Remote Power Controllers E-1071-623/627
are electronic control modules suitable for inductive loads such as
electromagnetic valves (solenoids), magnetic brakes etc.
They are used:
•
for safe and quick switching of loads
•
for monitoring the electrical condition of the loads
•
for compensating different cable lengths
The load connected to the relay should be operated with a higher voltage
(DC 28...60 V) than its rated voltage (DC 24 V) because the load current
is controlled electronically (pulse-controlled characteristics). This is
to ensure that in industrial plants with different cable lengths (supply
cables, load cables) an increased inrush current can be applied to
each load. During hold duty the load current is reduced to a smaller
value (approx. 60 % of the current rating), thus reducing the operating
temperature and extending the life of the loads.
The double pole electronic switching output prevents inadvertent
start-up or dangerous machine movements as may arise upon a
ground fault in systems with ungrounded power supply ('IT systems')
(see EC Machinery Directive or EN 60204 part 1 "Safety of Machinery
- Electrical Equipment of Machines", para 9.4.3.1).
Typical applications
●
Double pole switching of inductive actuators such as electromagnetic
valves or magnetic clutches in machinery and equipment
●
Monitoring the electrical operability of loads
●
Protection and monitoring of load circuit cables
●
Status indication, failure indication in load circuit visually
(via LEDs or red tripped button) and via potentialfree status outputs
●
Double pole split up of the load circuit manually or electrically in
the event of overload or short circuit
Features
●
Designed for inductive loads (DC 24 V)
●
Individual adjustment to various load currents
(standard: I
= 0.1...3.1 A and/or 10 mA...310 mA)
N
●
Significant reduction of power loss in the load by pulse-controlled
characteristics
●
Double pole switching output, short-circuit proof (short-circuit
limitation); physical disconnection from supply
●
Inrush current and holding current monitoring
●
Physical isolation:
- optocoupler in the control circuit
- physical disconnection of load circuit, manually or in the event
of a short circuit
- optocoupler for status outputs
●
Reverse polarity and overvoltage protection in the control, load
and status circuits
●
Control current indication by YELLOW LED
●
O.K. indication by GREEN LED
●
Wire break indication by RED LED (load circuit)
●
Fault indication by RED LED
(short circuit, over/undervoltage, setting error)
●
Two status outputs for PLCs for evaluation
(status indication, ON indication)
●
Quick disconnection (do not connect a free-wheeling diode to the
load as the free-wheeling current is controlled electronically)
Break time < make time
Issue C
Technical data (T
Rated voltage
Operating voltage U
B
Current rating I
N
Current consumption I
(U
= »0«)
S
Residual ripple for
all voltages
Reverse polarity protection U
Fail Save
Insulation voltage
Load circuit
Load output
Load rating
Switch-on current I
E
Holding current I
H
Short circuit
disconnection current
Wire break monitoring
Physical isolation
Current measuring plugs
Free-wheeling circuitry
(see Technical description)
Control circuit
Control
Control voltage U
S
Control current I
S
Switching frequency f
Control signal (U
= »1«)
S
Protection
Status outputs
2 signal outputs
ON indication
(terminal 8)
Function indication
(terminal 9)
www.e-t-a.com
623/627
E-1071-623
= 25 °C, U
= DC 48 V)
ambient
B
DC 48 V
DC 28...60 V
(see Technical description)
adjustable between 0.1...3.1 A and/or
10...310 mA via switch and potentiometer
on the front side
0
typically 16 mA
max. 5 % (3 phase bridge)
(terminals 1 and 2), integral
B
fuse
2.5 KV between load circuit, control circuit
and status signal circuit
NPN transistor, minus switching,
pulse-controlled (approx. 180 Hz)
DC 24 V/adjustable between 0.1...3.1 A or
DC 24 V/adjustable between10...310 mA
up to 10 % more than pickup current
typically 60 % of the set rated current I
approx. 4.5 A
in the ON and OFF condition (RED LED)
2-pole in the load circuit,
by manual circuit breaker release
or after short circuit disconnection
2 x ø 2 mm (current proportional voltage:
^
1 V = 1 A )
integral electronic control with quick
disconnection
optocoupler in control input
»0« = DC 0...5 V
»1« = DC 8.5...35 V
typically 5...10 mA
1 Hz
max
YELLOW LED lights (I
control
reverse polarity protection (diode)
ON indication/function indication
- physically isolated by optocoupler
- transistor outputs, plus switching
- auxiliary voltage U
: DC 12...60 V
A
- max. 50 mA per output
- integral free-wheeling diode
- reverse polarity and overvoltage
protection
U
= »0« : output non-conductive
S
< 70 ms switch-off signal delay
U
= »1« : output connecting plus potential
S
(term. 10) to term. 8 only as long
as load current flows, not with
wire break or short circuit
< 15 ms switch-off signal delay
fault: output non-conductive
no fault: output connecting plus potential
(terminal 10) to terminal 9
N
6
flowing)
6 - 49