To ensure the most effective operation of your Garden Master AWTS system you should
familiarise yourself with the contents of this manual. The Garden Master AWTS has been
designed to include additional safety margins and minor mishaps and normal household
usage will not usually affect the operation of the system.
However if the alarm sounds or strong odours persist this checklist may assist in
locating the fault.
Fault Observed
Alarm sounds
Water around tank
Excessive foaming
Persistent odours
Irrigation system not
working
Water ponding on
irrigation field
Wastewater Australia Pty Ltd
321 New England Highway Rutherford NSW 2320
10
Telephone: 1800 480 322 | Email:
www.gardenmaster.com.au
Master
Potential Cause
* Irrigation pump not working
* Air supply not working
* No power at the tank
* Irrigation pump not working
* Irrigation lines blocked or kinked
* Too much laundry detergent
* Too many washes
* Too much water usage
* Excessive chemicals in use
* Pump failure
* Irrigation lines blocked
* Not enough sprinklers working
* Excessive water use
* Broken irrigation pipe
ABN: 84 134 670 796

Fault Finding

for your AERATED
TREATMENT SYSTEM
Remedial Action
* Check water levels
* Listen for the air compressor
* Check power supply source
* Check water levels
* Check irrigation lines and clear sprinklers
* Use recommended quantities
* Spread wash loads over different days
* Add biologic starter pack
* Install water saving devices
* System will recover
* Check water level
* Clear lines and sprinklers
* Installation should comply with original approval
* Install water saving devices
* Repair irrigation pipe