Improperly connecting the grounding wire can result in the risk of electrical shock.
Check with a qualified electrician if you are in doubt as to whether the outlet is
properly grounded. Do not modify the plug provided with tool. Never remove the
grounding prong from the plug. If the cord or plug is damaged, have it repaired
before using. If the plug will not fit the outlet, have a proper outlet installed by a
qualified electrician. The USA5 must be plugged into an appropriate outlet, prop-
erly installed and grounded in accordance with all codes and ordinances. The
plug and outlet should look like those in Figure A.
s
®
do not use
lugger
drilling machines on surfaces or materials being
.
welded
doing so can result in personal injury and
s
®
lugger
drilling machine
Use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole receptacles that accept the tool's
plug. Replace or repair damaged cords. Make sure your extension cord is in good condition. When using an extension
cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop
in line voltage resulting in loss of power and overheating. Jancy recommends using a minimum 12 gauge extension cord
not to exceed 100 feet. The table below is supplied only as a guide to minimum gauge for extension cords, where the
smaller the gauge number, the heavier the cord.
minimum gauge for extension cords
volts
total length of cord in feet
120V
0-25
26-50
240V
0-50
51-100
amperage
0-6
18
16
6-10
18
16
10-12
16
16
12-16
14
12
recommended wire gauge
:
note
jancy recommends using a minimum
100
extension cord not to exceed
guideline for usa5 shift lever position
6
grounding instructions
WARNING!
WARNING!
.
extension cords
51-100
101-150
101-200 201-300
16
14
14
12
14
12
not recommended
12
gauge
.
feet
/
or damage to the
DRIP LOOP: To help prevent cutting fluids from traveling
along power cord and contacting power source, tie a drip
loop in power cord as shown in Figure B.
Fig. B