Jandy CV Versa-Plumb Series Kurulum ve Kullanım Kılavuzu - Sayfa 7

Yüzme Havuzu Filtresi Jandy CV Versa-Plumb Series için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Jandy CV Versa-Plumb Series 20 sayfaları. Cartridge pool filters
Ayrıca Jandy CV Versa-Plumb Series için: Kurulum ve Kullanım Kılavuzu (20 sayfalar), Kurulum ve Kullanım Kılavuzu (20 sayfalar)

Jandy CV Versa-Plumb Series Kurulum ve Kullanım Kılavuzu
#12x1" Pan Head
Stainless Steel
Screw (Qty 8)
Anchor
Bracket
(Qty 4)
Filter Tank Anchor Bracket Installation
Figure 3.
Anchor Bracket Installation
Figure 4.
Pressure Gauge/Air Release Assembly
on the tank adapter to tighten. Do not
overtighten.
b.
Place the larger, thinner o-ring onto the
gauge housing. Thread the housing into the
coupler on the tank adapter.
desired position. Raise and thread the locknut
assembly. Hand tighten the nut only. Using
a wrench to tighten the nut may damage the
nut, gauge or air release assembly.

3.4 Filter Plumbing

properly and operated without air in the water
2.
If the system can be subjected to higher pressure
than the maximum rating of any component,
install an ASME approved automatic pressure
relief valve or pressure regulator in the circulation
system. Set the relief valve or pressure regulator to
lowest working pressure of any of the components
in the system.
Cartridge Pool Filters - CL and CV Series Filters
1/4" x 2-1/4" S.S. Tapcon
Screw and S.S. Washer
Drill 5/32" Hole
Tank Bottom
Housing
O-Ring
Tank Adapter
Tank Adapter to Housing
Coupler
O-Ring
#12x1" Stainless Steel Pan
Head Screws (Qty 2)
Drill Two 3/32" Holes
Through Filter Base
Mounting Bracket
Anchor Bracket to Platform Installation
recommended for plumbing the system.
Sweep Elbow for this purpose. The sweep
elbow also includes a threaded port and plug
pressure testing. See Figure 7.
5.2 To install the sweep elbow use the following
instructions:
To avoid an electrical shock hazard, which can result
in serious injury or death, ensure that all electrical
power to the system is turned off before approaching,
inspecting or troubleshooting any leaking valves
or plumbing that may have caused other electrical
devices in the surrounding area to get wet.
Follow all filter manufacturer's
instructions. NEVER attempt to
assemble, disassemble or adjust the
filter when there is pressurized air in the
system. Starting the pump while there
is any pressurized air in the system can
cause the filter lid to be blown off, which
can cause death, serious personal
injury or property damage.
a.
Switch off the circuit breaker to the
equipment and open the air relief valve on
procedure).
NOTE
Page 7
Filter Base
Mounting Tab
3-1/2" Thick
(Min.)
Concrete Pad
WARNING
WARNING