Jandy Jandy Pro Series Kurulum ve Kullanım Kılavuzu - Sayfa 11

Yüzme Havuzu Filtresi Jandy Jandy Pro Series için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Jandy Jandy Pro Series 20 sayfaları. Single element cartridge pool & spa cs filters
Ayrıca Jandy Jandy Pro Series için: Kullanıcı El Kitabı (12 sayfalar), Kurulum Kılavuzu (16 sayfalar), Kullanıcı El Kitabı (20 sayfalar), Manuel (8 sayfalar), Hızlı Başlangıç Kılavuzu (2 sayfalar), Kurulum ve Kullanım Kılavuzu (20 sayfalar), Kurulum Talimatları (2 sayfalar), Kurulum ve Kullanım Kılavuzu (16 sayfalar), Kurulum ve Kullanım Kılavuzu (16 sayfalar), Kurulum ve Kullanım Kılavuzu (16 sayfalar)

Jandy Jandy Pro Series Kurulum ve Kullanım Kılavuzu
Jandy
3.2.4.3 Pump Dip Switch Settings
As shown in Figures 5 and 6 the 4 position dip switch
serves two (2) functions: it selects the pump address,
and it determines what type of controller will be used
with the pump.
Table 2.
Dip Switch Settings
Switch 1 Switch 2 Controller
OFF
OFF
Factory Default
OFF
OFF
AquaLink
or AquaLink Z4
ON
ON
Variable Speed Controller
Switch 3 Switch 4 Pump Address
OFF
OFF
PUMP 1 (Factory Default)
ON
OFF
PUMP 2
OFF
ON
PUMP 3
ON
ON
PUMP 4
3.2.5 Auxiliary Load Operation
The VS PlusHP is equipped with a terminal bar that
provides user access to a built-in Auxiliary Load relay
contact. This normally-open, dry contact is activated
under certain operating conditions and is primarily
intended to be used to control external devices that
require system water flow for proper functioning, such
as heaters, booster pumps, salt water chlorinators, etc.
See Figures 5 and 6 for compartment's location details.
An access cover with Phillips-head screw must be
removed before proceeding.
3.2.5.1 Auxiliary Load Connection
Requirements
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or injuries
to persons, Zodiac
Pumps and any auxiliary loads must
®
be installed in accordance with the National Electrical
Code
(NEC
), all local electrical and safety codes, and
®
®
the occupational Safety and Health Act (OSHA). Copies
of the NEC may be ordered from the National Protection
Association, 470 Atlantic Ave., Boston, MA 02210, or
from your local government inspection agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
• THE Auxiliary Load relay contacts are rated at
230V/11A RMS. Please ensure the requirements of
the equipment to be connected to the Auxiliary Load
do not exceed this rating.
Pro Series VS PlusHP Pumps
®
RS, AquaLink PDA,
®
WARNING
|
Installation & Operation Manual
TP133
TP130
/100
TP127
L1
GFCI-
(Black)
Protected
230V
Power
L2
Source 2
(Red or Black)
Earth
Figure 7. 230V Auxiliary Load, Separate Power Sources
Wiring Diagram
TP133
TP130
/100
TP127
Line
GFCI-
(Black)
Protected
115V
Power
Neutral
Source
(White)
Earth
Figure 8. 115V Auxiliary Load, Separate Power Sources
Wiring Diagram
3.2.6 Auxiliary Load Operation
Characteristics
Auxiliary Load relay contact activation is speed-
dependent, and behaves as follows:
3.2.6.1 Contact Closure
From a stopped condition, there is a three-minute delay
before the Auxiliary Load contact is closed when the
motor speed reaches and maintains a speed of at least
1725 RPM.
From a running condition at below 1725 RPM, there is
a five-second delay before the Auxiliary Load contact
is closed when the motor speed reaches and maintains a
speed of at least 1725 RPM.
ENGLISH
1
2
L2 L1
F1015
F1014
Earth
EXAMPLE ONLY
Line
NOT Representative of
(Black)
all wiring configurations
230V
Auxiliary
Load
Note: Recommended Wiring Configuration
1
2
L2 L1
F1015
F1014
Earth
Line
EXAMPLE ONLY
(Black)
NOT Representative of
all wiring configurations
115V
Auxiliary
Load
Page 11
L1
GFCI-
(Black)
Protected
230V
Power
L2
Source 1
(Red or
Black)
L1
GFCI-
(Black)
Protected
230V
Power
L2
Source
(Red or
Black)