3.7

Vanishing Edge Pool Installation

Figure 9 shows the installation of a pool with a
vanishing edge design.
Vanishing Edge Pool
*Install sensor such that long probe tips are close to Minimum Operating Level and short tip is close to High Water Level.
NOTE When mounting a slip sensor on a static pipe, glue 1" fittings with 793 IPS brand ABS/PVC glue.
Do not glue 2" fittings.
Figure 9. Installation of Vanishing Edge Pool
Jandy Pro Series Levolor
Models K-2000
Catch Basin
1" Coupling
High Water Level
High Water Sensor Probe*
Sensor Common Probe*
Minimum Operating Water Level
Fill Sensor Probe*
II Electronic Water Leveler
®
Conduit to Sensor Control
System at Control Box
Bond Beam
|
Installation and Operation Manual
Remote Sensor Housing
½" Conduit Connection
1" P.V.C. Equalizer Line