Section 5. Troubleshooting
Tools required: Multimeter that can read AC and DC
voltage and No. 6 Phillips screwdriver.
5.1
Observations at Job Site
Make these initial observations when at the jobsite.
1.
Proper wire usage between the controller and the
valve. (Direct-burial style polypropelene-jacketed
solid-core wire (at least 18-gauge wire): the same
wire as the sensor wire.)
2.
Proper wire nuts at the valve connection. (Grease-
filled wire nuts or gel caps. Conventional wire
nuts filled with silicone will not work since some
silicones have acids that degrade copper wires.)
3.
Sensor wire is continuous and not spliced. (No
splices between the tips and the controller.)
4.
Proper use of appropriate sensor and location: slip
style for static pipes.
5.
Proper power input voltage to the box and proper
wiring for the voltage (110 or 220VAC).
6.
Remove top face plate to verify that control lights
on PCB line up with plastic lenses on the plate.
NOTE Before making changes to connections or
settings, reset the controller by powering off for
10 seconds and then powering back on.
Jandy Pro Series Levolor
II Electronic Water Leveler
®
Models K-2000
5.2
5.2.1 Prepare the Control Unit
1.
Turn off the power to the control box before starting
this procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
Be sure to separate wires so that they are not
touching each other or damage may result to the
control box.
2.
3.
Table 5. Valve and Relay Connections
Valve or Relay
Valve Wires
Relay Wires
|
Test Operation of Control Unit
Shut power off to the control box.
WARNING
CAUTION
Disconnect the sensor from the sensor wires. Refer
to Figure 7, Control Box Wiring, on page 10, and
Table 1, Sensor Wire Connections, on page 11.
a.
Disconnect the black wire for the Sensor
Common probe from the yellow wire in the
control box.
b.
Disconnect the red wire for the Fill Sensor
probe from the yellow wire with the blue
stripe in the control box.
c.
Disconnect the white wire for the High Water
Sensor probe from the yellow wire with the
red stripe in the control box.
Disconnect the valve and the relay from the
control box. Refer to Figure 7, Control Box
Wiring, on page 10,
and Table 5, shown below.
a.
Disconnect the valve from the blue
the control box.
b.
Disconnect the relay from the red and gray
wires in the control box.
Installation and Operation Manual
wires in
Control Box Wires
Blue
Red and Gray