Gardena 1468 Operatör El Kitabı - Sayfa 5

Su Pompası Gardena 1468 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Gardena 1468 9 sayfaları. Submersible pressure pump

Gardena 1468 Operatör El Kitabı
The power cable of the Submersible Pressure Pump must be connected
to a socket which is positioned at a height of 1.10m (measured from ground).
Take care that the power cable leads downwards.
Data indicated on the type plate must match technical data of the mains supply.
v Consult your qualified electrician.
v Take care that the electrical connections are made within dry area, protected
from flooding.
v Keep mains plug dry.
Protect plug and power cable from heat, oil and sharp edges.
The power cable must not be used for mounting or relocating the pump. For sub-
merging or lifting / securing the pump, please use the fastening rope.
In Austria
In Austria the electrical connection must satisfy the ÖVE-EM 42, T2 (2000) / 1979
§ 22 to § 2022.1. This requires that pumps used for swimming pools and garden
ponds may only be powered through an isolating trans former.
v Please ask your electrician for his advice.
In Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected
via a residual-current device.
Notes on use
When connecting the pump to the water supply system, the country-specific
sanitary regulations must be observed to prevent water not of drinking water
quality being drawn back in.
v If necessary, contact your sanitary expert.
Sand and other abrasive substances cause increased wear and reduce the
pump's output.
During operation, the pump must always be submersed in the water up to the
minimum submersion depth (see 6. TECHNICAL DATA)
Do not allow the pump to run for more than 10 minutes against the closed
pressure side (e. g. closed valve, closed dispenser etc.).
Leaking lubricants can contaminate the pumped liquid.
DANGER! This product makes an electromagnetic field while it operates. This
field may under some conditions interfere with active or passive medical implants.
To decrease the risk of conditions that can possibly injure or kill, we recommend
persons with medical implants to speak with their physician and the medical
implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-
bag can suffocate toddlers. Keep toddlers away when you assemble the product.

2. INITIAL OPERATION

Connect hose via the GARDENA Connection System [ Fig. I1 ]:
19 mm (3/4")- / 16 mm (5/8") and 13 mm (1/2") hoses can be connected
via the GARDENA Connection System.
Hose diameter
Pump connection
Pump Connection Set
13 mm (1/2")
GARDENA Tap Connector
16 mm (5/8")
GARDENA Hose Connector
19 mm (3/4")
GARDENA Pump Connection Set
The pump connection component
facturer together with the check valve
Connect hose via the relevant GARDENA Connection System.
v
ß
Backflow preventer
[ Fig. I1 ]:
v
ß
The backflow preventer
prevents the hose from running empty after the
v
pump has been turned off or taken out of operation.
With a parallel connection of more than one hose or connected devices,
the GARDENA 2­ / 4­Way Valve (Art. 8193 / 8194) can be used, which
is screwed straight onto the pump connection piece
Pump installation [ Fig. I2 ]:
The pump must always be submerged in the fountain or water reservoir
with the fastening rope
3
provided. For the pump to be primed,
the pump must be submerged to the minimum submersion depth
(see 6. TECHNICAL DATA) So that the filter does not become dirty, the
pump should be fixed at least 30cm above the ground.
3
1. Attach the fastening rope
to the handle
2. Submerge pump in the fountain or water reservoir via the fastening
3
rope
.
3
3. Secure fastening rope
.
4. With deep fountains or shafts (from approx. 5m), route the connection
cable
5
along the fastening rope
Art. 1750
Art. 18202
Art. 18216
Art. 1752
1
is already pre-installed by the manu-
ß
.
v
1
.
ß
4
.
3
with clips.
Thermal protection switch:
In the event of an overload, the pump is switched off by the built-in
thermal motor protection. After sufficient cooling of the motor, the pump
is operational again.
3. OPERATION
Automatic operation [ Fig. O1 ]:
6
The float switch
turns the pump on automatically when the water level
exceeds the cut-in height and the water is pumped out. The float switch
6
turns the pump off again as soon as the water level falls below the
cut-out height.
v During automatic operation, ensure that the float switch
move freely.
Adjusting the Cut­in and Cut­out Height:
The cable length between the float switch
must always be at least 10 cm.
1. Press the cable of the float switch
float switch lock
7
.
Do not select a cable length that is too long or short to ensure that the
float switch can turn on and off properly.
2. Plug the mains plug of the connection cable
The pump is now ready for operation.
• The higher the opening of the float switch lock
the cut-in and cut-out height.
• The shorter the length of cable between the float switch
and the float switch lock
the cut-out height.
Manual operation:
The pump remains in constant operation when the float switch is attached
facing upwards so that the cable is pointing downwards.
v Attach the float switch
The residual water height of approx. 25 mm is only reached during
manual operation since the float switch turns off the pump during auto-
matic operation before this water level is reached.
4. STORAGE
To put into storage:
The product must be stored away from children.
v Store the pump away from frost before the first frost sets in.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste. It
must be disposed of in line with local environmental regulations.
IMPORTANT!
Dispose of the product through or via your municipal recycling collection
centre.

5. TROUBLESHOOTING

DANGER! Electric shock!
There is a risk of injury from electric shocks.
v Before maintenance, disconnect the submersible pressure
pump from the mains.
t
Problem
The pump does not
deliver any water
6
and the float switch lock
6
into an opening in the
5
into a mains socket.
7
, the higher
7
, the lower the cut-in height and the higher
6
to the top so that the cable points downward.
Possible Cause
Remedy
Air cannot escape as the
v Open pressure line
pressure line is closed.
(e. g. bent pressure hose).
Air cushion in suction foot.
v Unplug mains cable and
plug in again.
When starting the pump,
v Submerge pump deeper
water height falls below the
(see 6. TECHNICAL DATA /
min. water level.
Minimum submersion depth
on commissioning).
6
can
7
6
7