Gardena 1734 Operatör El Kitabı - Sayfa 5
Su Pompası Gardena 1734 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Gardena 1734 10 sayfaları. Garden pump
Ayrıca Gardena 1734 için: Kullanım Talimatları Kılavuzu (10 sayfalar), Operatör El Kitabı (10 sayfalar), Kullanım Talimatları Kılavuzu (17 sayfalar)
Extension cables
Date indicated on the type plate must match technical data of the mains supply.
Only use extension cables authorised in accordance with HD 516.
v Consult your qualified electrician.
v Don't use the power cable for carrying the pump or for plugging off.
In Austria
In Austria, the electrical connections must be made according to ÖVE-EM 42,
T2 (2000) / 1979 § 22 based on § 2022. Pursuant to this regulation it's imperative
to operate pumps for swimming pools and garden ponds exclusively via an isola-
ting transformer.
v Please ask your electrician.
In Switzerland
In Switzerland mobile appliances which are used outdoors, must be connected
via a residual- current device.
Visual check
v Before operating the pump, first make a visual cheek, if there is any damage
of the pump (esp. regarding power cable and plug).
A damaged pump must not be used.
v In case of damage, please have the pump checked by our GARDENA Service
Centre or by an authorised electrician.
v If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
Note
v Protect the pump from rain. Don't use the pump in wet or moist area.
In order to avoid dry-running of the pump, take care that the end of the suction
hose is always submerged into the liquid.
v Before each operation, fill the pump to overflowing with approx. 2 to 3 l of the
liquid to be pumped!
Sand and other abrasive substances in the liquid cause in-creased wear and
reduce the pump's output.
Pumping dirty water, e.g. stones, pine needles etc., can cause damage to the
pump.
v Do not pump dirty water.
The minimum flow rate is:
4000/5: 90 l/h (= 1.5 l/min);
5000/5: 200 l/h (= 3.3 l/min).
Watering accessories with lower rate must not be operated.
DANGER! This product makes an electromagnetic field while it operates. This
field may under some conditions interfere with active or passive medical implants.
To decrease the risk of conditions that can possibly injure or kill, we recommend
persons with medical implants to speak with their physician and the medical
implant manufacturer before you operate the product.
DANGER! Small parts can be easily swallowed. There is also a risk that the poly-
bag can suffocate toddlers. Keep toddlers away when you assemble the product.
2. INITIAL OPERATION
Setting up your Garden Pump:
The site must be firm and solid in order to ensure safe and sturdy operat-
ing conditions for the pump.
v Position the pump at a safe distance (min. 2 m) from the liquid to be
pumped.
The pump must be installed in a location with low air humidity and
sufficient ventilation in the area of the ventilation slots. It must be at
a distance of at least 5 cm from the walls. No dirtcontamination
(e. g. sand or earth) may be sucked in through theventilation slots.
Connecting hose to suction side [ Fig. I1 ]:
Don't use any hose connection system fittings on the suction side!
A vacuum-resistant suction hose must be used, e. g. GARDENA
Suction Unit, Art. 1411.
In order to reduce the suction time, it is advisable to use a suction hose
with backflow preventer avoiding automatic draining of the suction hose
when the pump is stopped.
1. Screw a vacuum-resistant suction hose
on the suction side of the pump
2. For suction heights exceeding 4 m also secure the suction hose
(e. g. by fastening it to a wooden post).
This relieves the pump of the weight of the suction hose.
Connecting hose to delivery side [ Fig. I2 ]:
The pumps have 2 connections
3
The pump connection not in use has to be closed by the cap
can be unscrewed for connecting 2 hoses.
8
1
airtight onto the connector
2
.
/
ß
on the delivery side.
3a
4
, which
The pump connections
which can be used to connect 13 mm (1/2"), 16 mm (5/8") or
19 mm (3/4") hoses via the GARDENA hose connection system.
Optimised use of the pump capacity is achieved by connecting 19 mm
(3/4") hoses with e.g. GARDENA Pump Connection Set Art. 1752, or by
connecting 25 mm (1") hoses with GARDENA Quick Thread Coupling
with female thread Art. 7109 / Quick Coupling Hose Connector
Art. 7103.
v Connect the pressure hose
side
3
/
ß
.
3a
If more than 2 hoses / accessories are connected simul taneously, we
recommend using the GARDENA 2- or 4-Channel Water Distributor
Art. 8193 / 8194, GARDENA Twin-Tap Connector Art. 940 which
can be screwed directly onto the connection on the delivery side
3. OPERATION
Filling the pump [ Fig. O1 / O2 ]:
DANGER! Electric shock!
Risk of injury due to electric current.
v Disconnect from the mains before filling the Garden Pump.
CAUTION!
v Before each operation, slowly fill the pump with liquid to be
pumped until it overflows (approx. 2 to 3 l).
1. Twist off the cover
anti-clockwise.
2. Fill the pump via the filler cap
the liquid to be pumped.
6
3. Twist on cover
with the key
(do not over-twist).
4. Open any shut-off valves in the delivery line (accessories, water stop,
etc.).
5. Drain remaining water in pressure hose
during the suction process.
6. Switching on pump 4000/5:
Lift and hold the delivery hose
pump, press the On/Off switch
until the pump has primed.
v If the pump does not deliver after approx. 5 minutes,
switch off the pump (press On/Off switch
(see 6. TROUBLESHOOTING).
6. Switching on pump 5000/5; 6000/6 inox [ Fig. O3 / O4 ]:
Lift and hold the delivery hose
pump, insert the power plug, press the On/Off button
(the LED shines green) and wait until the pump has primed.
If the pump does not deliver within approx. 20 seconds, the LED
flashes orange.
If the pump does not deliver: 5000/5 within approx. 5 minutes /
6000/6 inox within approx. 6 minutes, the LED shines red and the
pump switches off auto matically (see 6. TROUBLESHOOTING).
v If the pump does not automatically switch off then manually
switch the pump off and check the hose for leaks.
The specified maximum self-priming suction height of 8 m is reached
only if the pump is filled via the filler neck
while doing so and during the self-priming, the delivery hose
up sufficiently high to prevent any flow medium escaping from the pump
5
via the delivery hose
Special mode:
Additional electrical switching devices (e. g. remote control systems,
pressure switches) can be used only in the special mode.
Activating the special mode:
1. When switching on, press the On/Off button
1
During the first 5 seconds, the green LED is illuminated;
then the LED blinks for 3 seconds.
2. When the green LED illuminates again after 8 seconds, let go of the
ß
On / Off button
.
8a
Deactivating the special mode:
1. Plug the mains plug into an energised mains socket.
The pump starts of its own accord.
3
ß
/
are equipped with a 33.3 mm (G 1") thread
3a
5
to the connector on the delivery
6
on the filler
7
with the accompanying key
7
to overflowing with approx. 2 to 3 l of
.
clockwise only to the stop
5
so that air can escape
5
at least 1 m vertically above the
8
(On/Off switch shines) and wait
8
)
5
at least 1 m vertically above the
7
up to the overflow and if,
.
ß
for 8 seconds.
8a
3
/
ß
.
3a
.
<
ß
8a
5
is held