Gardena 9049 Operatör El Kitabı - Sayfa 5

Su Pompası Gardena 9049 için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. Gardena 9049 12 sayfaları. Clear/dirty water submersible pump

Gardena 9049 Operatör El Kitabı
1. SAFETY
Important! Read the operator's manual carefully before use and
keep for future reference.
Symbols on the product:
Read operator's manual.
General safety warnings
Electrical safety
DANGER! Electric shock!
Risk of injury due to electric shock.
v The product must be supplied through a residual current device (RCD)
having a rated residual operating current not exceeding 30 mA.
v Contact GARDENA Service if the Residual Current Device (RCD) has
triggered.
DANGER! Risk of injury!
Risk of injury due to electric current.
v Disconnect the product from the mains before you maintain or replace
parts. Thereby the disconnected socket must be in the visual range.
Safe operating practices
The water temperature should not exceed 35 °C.
The pump must not be used when people are in the water.
Pollution of the liquid could occur due to leakage of lubricants.
Do not use below + 3 °C ambient / media temperature.
Keep bystanders away from the water.
Operate the pump only with the elbow connector.
The hose end should be lower than the maximum delivery head.
Circuit breakers
Thermal protection switch:
In the event of an overload, the pump is switched off by the built-in thermal motor
protection. After sufficient cooling of the motor, the pump is operational again.
Automatic venting
This pump is equipped with a vent valve which eliminates any air pockets in the
pump. Depending on the function, a small amount of water can escape from the
side of the housing.
Additional safety warnings
Electrical safety
DANGER! Cardiac arrest!
This product makes an electromagnetic field while it operates. This
field may under some conditions interfere with active or passive medical
implants. To decrease the risk of conditions that can possibly injure or
kill, we recommend persons with medical implants to speak with their
physician and the medical implant manufacturer before you operate the
product.
Cables
If extension cables are used, these must comply with the minimum cross-
sections in the table below:
Voltage
Cable length
230 – 240 V / 50 Hz
Up to 20 m
230 – 240 V / 50 Hz
20 – 50 m
DANGER! Electric shock!
With a cut off mains plug, moisture can get into electrical parts via the
mains cable and cause a short circuit.
v Never cut the mains plug off (e. g. to feed through wall).
v Don't use the power cable for plugging off.
v If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Mains plug and extension connections must be protected from water splashes.
Ensure that the electrical connections for plugs and sockets are made in areas
safe from flooding.
Protect the mains plug and the mains power cable from heat, oil and sharp
edges.
Observe the mains voltage. The information on the nameplate must be in agree-
ment with the data for the mains power grid.
The pump's mains plug must be disconnected before anybody enters the swim-
ming pool or touching the surface of the water.
The mains power cable must not be used for fastening or transporting the pump.
For submerging or lifting / securing the pump, please use a fastening rope. Do not
use the power cable to lift the pump.
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the
power connections) to a visual inspection.
A pump which is damaged should not be used. In the event of damage, have the
pump checked by GARDENA Service.
Assembly instructions: Retighten all screws by hand.
Before use after maintenance, make sure that all parts are screwed together.
When using our pumps with a generator, the warnings of the generator manu-
facturer must be observed.
Personal safety
Small parts can be easily swallowed. There is also a risk that the poly-
bag can suffocate toddlers. Keep toddlers away when you assemble the
product.
Please be sure not to use the clear water function to pump dirty water. It can lead
to blockage and overheating of the pump.
Observe the minimum water level in accordance with the characteristics given
for the pump.
Allow the pump to run no longer than 10 minutes against a closed pressure
side.
Sand and other abrasive substances cause increased wear and reduce the
pump's output.
The sensor fields may only be operated outside the water.
The hose must not be disconnected during operation.
Allow the pump to cool down before troubleshooting.
2. ASSEMBLY
v Disconnect the product from the mains before you assemble
To remove the handle lock [ Fig. A6 ]:
The handle lock
first time.
1. Pull the attached handle locks
2. Keep them for later securing procedures (e. g. transport or storage).
Connection possibilities of the connection nipple [ Fig. A1 ]:
The hose can be connected via the connection nipple
hose diameters.
Large hose diameter
Medium hose diameter
Small hose diameter
When using the largest hose diameter, the pump has the maximum
delivery capacity.
Cross section
Pump
1.5 mm
2
Small hose diameter
2.5 mm
2
Art. GARDENA Hose Clamp
Medium hose diameter
Art. GARDENA Hose Clamp
Large hose diameter
Art. GARDENA Hose Clamp
When using the 38 mm (1 1/2") hose, we recommend the GARDENA
Flat Hose Set Art. 5005 with 10 m hose and hose clamp.
To connect the hose via the connection nipple:
1. When using the large diameter hose, cut off the connection nipple
at
2. When using the medium hose diameter, cut off the connection
nipple
3. Push the hose onto the connection nipple
4. Fix the hose to the connection nipple
Clamp.
DANGER! Risk of suffocation!
DANGER! Risk of physical injury!
Injury when the product starts accidentally.
the product.
(C)
must be removed before the product is used for the
(C)
outwards.
Cut off nipple at
Cut off nipple at
Do not cut off nipple [ Fig. A4 ]
Art. 9049
32 mm (1 1/4")
Art. 7194
38 mm (1 1/2")
Art. 7195
51 mm (2")
Art. 7196
(a)
.
(4)
at
(b)
.
(4)
with different
(a)
[ Fig. A2 ]
(b)
[ Fig. A3 ]
(4)
(4)
.
(4)
e. g. with a GARDENA Hose
9