KitchenAid andRetractable Downdraft Kurulum Talimatları Kılavuzu - Sayfa 2

Havalandırma Davlumbazı KitchenAid andRetractable Downdraft için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. KitchenAid andRetractable Downdraft 9 sayfaları. 30” and 36” retractable downdraft vent systems

KitchenAid andRetractable Downdraft Kurulum Talimatları Kılavuzu
LUUII
I~I
UII
I I~I
Isions
See cooktop
Cutout width:
manufacturer's
30" vent -
2J-
112"
instructions
for
,,4"
-:-
-..1-...
m,n, curour
36" vent - 33-112"
cooktop
cutout
depth and width.
--..
A = cabinet
wall
to rear line of
cutout
\
countertop
Allow
l/2" from
rear of downdraft
vent to back wall
of cabinet.
Left cabinet
wall cutout:
Use dimensions
for ductwork
cutout
location
that applies
to
your installation.
fl
',
I"
II
1 J-i/16"
Cabinet
centerline
II
I
I NOTE: Vent cutout
shown assumes
rear edge of
cooktop
overlaps
edge of downdraft
vent by 3/W.
Locate
power
supply
junction
box at lower right
corner
of cabinet.
Exterior-mounted
motor:
Cutout width:
Cutout width:
3@" wnnt
37-4 13"
1
3E
C
b
Allow 112" min.
from rear of
downdraft
vent
IA b8s.r
to back wall of
cabinet.
See cooktop
manufacturer's
instructions
for
cooktop
cutout
depth and width.
9" round hole can be
cut in floor, or right
or left side of
cabinet.
I
9" round
hois. Hsioht
Use dimensions
for
location
that applies
I
I
Ii
I --------
to your installation.
9" round hole.
as needed.
1-l
Height can vary
Locate power supply
junction
box at lower
right corner of
cabinet.
NOTE: Vent cutout
shown assumes
rear
edge of cooktop
overlaps
edge of
downdraft
vent by
318".
cutout
dimensions
Figure 1
Figure 2
Dimension A: If just a "Max."
dimension
is
given, that dimension
must be used.
*If dimension
A is between the "Min."
and
"Max.":
Subtract actual dimension "A" from
"A Max." Divide by 2.
Add to "C (for A Max.)" for required
C dimension.
Example:
KECSl 00, 1 g-3/8" cutout
"A Max."
20-518"
Actual "A"
- 19-318"
1 -l/4"
+ 2 = 518"
C (for A Max.)
9/l 6"
+
518"
l-3116" = Required
C
dimension
I I
( see
( size
( Gn.
( Mtx.
/
B
/ :$L~zo~:.(
x
(
Models
When installed
with
Figure
KIRD801
KECSlOP,
KGCTlOO'
2
30"
18-314" 20-5/8"
l-314"
l-1/2"
g/16"
27-l/2"
KIRD802 KECT305*, KGCT305*
KECC500, KECC502,
1
30"
~~~~~~ 20-l p
2"
j::':'::..
c '.'.:.:.~~~~:i:i:i:i:~
i~~~~~~~~~
27- 1 ,2 II -
. . . . . -.i-:.;-,-::
. . . . . . . . .
KECC507
.,...__
i:~:~;~~:~:~:~:::::::::::~:::~ -~-~i~-~iis'iiii~~ii
y.:.::::.:::.:.:.:.:.:::::::::::'
.:~~:~:~:~~~:~:~:~:~:iiI:I:I:::
. . ..__.... :::::... . . . . . . . . . .
KECN507
1
30"
19-l/4"
2-l/8"
27-l/2"
KIRD861
KECG260'.KGCG260*
2
36"
18-314" 20-518"
l-314"
l-112"
9116"
33-l/2"
IKIRD862 1 KECT365'. KGCT365' 1
1
1
I
I
1
KECN560,'KECN567
1
36"
~~~~I~I 19-l /4" 2- l/8"
KECC560, KECC567
1
36"
v
:~~~~~~~~~~~
20-l 12"
Retractable downdraft
.vent dimensions
C5/8"
2-518"
I
30" vent base width - 27"
36" vent base width - 33"
Interior-mounted
motor
8-114"
retractable
vent height
':
26-118"
30";ent
base width - 27"
36" vent base width -
33"
8"
8"
F
%-l/4"
retractable
vent height
Exterior-mounted
motor
Panel A